Evidence map›Paper›PMID 28648046›Full record

ArticleAnalytical chemistry2017

A Printed Equilibrium Dialysis Device with Integrated Membranes for Improved Binding Affinity Measurements.

Cody W Pinger, Andrew A Heller, Dana M Spence

Abstract read
In one paragraph

Article in Analytical chemistry, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Article
  2. Review
  3. 3D printed microfluidic devices with electrodes for electrochemical analysis.Analytical methods : advancing methods and applications · 2024
    Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Cody W PingerDepartment of Chemistry, ‡Department of Biomedical Engineering, and §Institute for Quantitative Health Science and Engineering, Michigan State University , 775 Woodlot Dr., East Lansing, Michigan 48824, United States.
Andrew A HellerDepartment of Chemistry, ‡Department of Biomedical Engineering, and §Institute for Quantitative Health Science and Engineering, Michigan State University , 775 Woodlot Dr., East Lansing, Michigan 48824, United States.
Dana M SpenceDepartment of Chemistry, ‡Department of Biomedical Engineering, and §Institute for Quantitative Health Science and Engineering, Michigan State University , 775 Woodlot Dr., East Lansing, Michigan 48824, United States.ORCID 0000-0002-4754-6671

Funding

Spatial SILAC: Examining the Proteome in 3D Cell CulturesR01GM110406 · NIGMS · UNIVERSITY OF NOTRE DAME · PI HUMMON, AMANDA B. · 2014 to 2022
$3.0M
A Novel Fluidic and Membrane-based Platform for Inhibiting Intercellular CommunicationR01DK110665 · NIDDK · MICHIGAN STATE UNIVERSITY · PI SPENCE, DANA M · 2016 to 2019
$1.6M
NIDDK NIH HHS R01 DK110665NIGMS NIH HHS R01 GM110406
6 · The paper itself

Abstract

Equilibrium dialysis is a simple and effective technique used for investigating the binding of small molecules and ions to proteins. A three-dimensional (3D) printer was used to create a device capable of measuring binding constants between a protein and a small ion based on equilibrium dialysis. Specifically, the technology described here enables the user to customize an equilibrium dialysis device to fit their own experiments by choosing membranes of various material and molecular-weight cutoff values. The device has dimensions similar to that of a standard 96-well plate, thus being amenable to automated sample handlers and multichannel pipettes. The device consists of a printed base that hosts multiple windows containing a porous regenerated-cellulose membrane with a molecular-weight cutoff of ∼3500 Da. A key step in the fabrication process is a print-pause-print approach for integrating membranes directly into the windows subsequently inserted into the base. The integrated membranes display no leaking upon placement into the base. After characterizing the system's requirements for reaching equilibrium, the device was used to successfully measure an equilibrium dissociation constant for Zn

Indexed as

DialysisPrintingBinding SitesHumansSerum Albumin, HumanZincSerum Albumin, HumanZinc

Identifiers

PMID28648046
PMCPMC5978405

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.