Evidence map›Paper›PMID 28643024›Full record

ArticleInternational journal of computer assisted radiology and surgery2017

Automatic seed picking for brachytherapy postimplant validation with 3D CT images.

Guobin Zhang, Qiyuan Sun, Shan Jiang, Zhiyong Yang, Xiaodong Ma, Haisong Jiang

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. An integrated navigation system based on a dedicated breast support device for MRI-guided breast biopsy.International journal of computer assisted radiology and surgery · 2022
    Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Guobin ZhangTianjin Key Laboratory of the Design and Intelligent Control of the Advanced Mechatronical System, Tianjin, 300384, China.
Qiyuan SunTianjin Key Laboratory of the Design and Intelligent Control of the Advanced Mechatronical System, Tianjin, 300384, China.
Shan JiangSchool of Mechanical Engineering, Tianjin University, Tianjin, 300350, China. shanjmri@tju.edu.cn.
Zhiyong YangSchool of Mechanical Engineering, Tianjin University, Tianjin, 300350, China.
Xiaodong MaSchool of Mechanical Engineering, Tianjin University, Tianjin, 300350, China.
Haisong JiangSchool of Mechanical Engineering, Tianjin University, Tianjin, 300350, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposePostimplant validation is an indispensable part in the brachytherapy technique. It provides the necessary feedback to ensure the quality of operation. The ability to pick implanted seed relates directly to the accuracy of validation. To address it, an automatic approach is proposed for picking implanted brachytherapy seeds in 3D CT images.

methodsIn order to pick seed configuration (location and orientation) efficiently, the approach starts with the segmentation of seed from CT images using a thresholding filter which based on gray-level histogram. Through the process of filtering and denoising, the touching seed and single seed are classified. The true novelty of this approach is found in the application of the canny edge detection and improved concave points matching algorithm to separate touching seeds. Through the computation of image moments, the seed configuration can be determined efficiently. Finally, two different experiments are designed to verify the performance of the proposed approach: (1) physical phantom with 60 model seeds, and (2) patient data with 16 cases.

resultsThrough assessment of validated results by a medical physicist, the proposed method exhibited promising results. Experiment on phantom demonstrates that the error of seed location and orientation is within ([Formula: see text]) mm and ([Formula: see text])[Formula: see text], respectively. In addition, the most seed location and orientation error is controlled within 0.8 mm and 3.5[Formula: see text] in all cases, respectively. The average process time of seed picking is 8.7 s per 100 seeds.

conclusionsIn this paper, an automatic, efficient and robust approach, performed on CT images, is proposed to determine the implanted seed location as well as orientation in a 3D workspace. Through the experiments with phantom and patient data, this approach also successfully exhibits good performance.

Indexed as

AlgorithmsBrachytherapyHumansImage Processing, Computer-AssistedImaging, Three-DimensionalLung NeoplasmsPhantoms, ImagingProstheses and ImplantsReproducibility of ResultsTomography, X-Ray ComputedBrachytherapyCT imageImplanted seedLocationSeed picking

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.