SynthesisSurgical endoscopy2018
Ultrasonographic optic nerve sheath diameter for predicting elevated intracranial pressure during laparoscopic surgery: a systematic review and meta-analysis.
Synthesis in Surgical endoscopy, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07784361 (Assessment of Increased Intracranial Pressure by Optic Nerve Sheath Diameter), which is not on this map. Cited by 18 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Assessment of Increased Intracranial Pressure by Optic Nerve Sheath Diameter (ONSD), Eyeball Transverse Diameter (ETD) and ONSD/ETD Ratio Measurement From Ocular Ultrasound
Who cites it
18 citing papers in PubMed, 42 citations in OpenAlex.
- Intraoperative optic nerve sheath diameter changes in vNOTES versus total laparoscopic hysterectomy: a prospective randomized study.Surgical endoscopy · 2026Trial
- Trial
- Effects of Supraglottic Airway Devices on Hemodynamic Response and Optic Nerve Sheath Diameter: Proseal LMA, LMA Supreme, and I-gel LMA.Medicina (Kaunas, Lithuania) · 2023Trial
- The effect of laryngoscope types on hemodynamic response and optic nerve sheath diameter. McCoy, Macintosh, and C-MAC video-laryngoscope.Saudi medical journal · 2020Trial
- Multimodal perioperative monitoring of intracranial pressure surrogates and cerebral oxygenation during laparoscopic surgery: implications for early cognitive outcomes.BMC anesthesiology · 2026Observational
- Non-invasive intracranial pressure estimation in the intensive care unit: narrative review of methods and clinical applications.Intensive care medicine · 2026Review
- Ultrasonographic evaluation of intraoperative optic nerve sheath diameter changes in patients undergoing laparoscopic surgery.BMC anesthesiology · 2026Observational
- Optic nerve sheath diameter and Pcv-aCOBMJ open · 2025Article
- Intracranial pressure estimated non-invasively and postoperative outcomes in surgery in the Trendelenburg position with pneumoperitoneum.Journal of anesthesia, analgesia and critical care · 2025Review
- Anesthetic Management of a Patient With Arnold Chiari Malformation and Syringomyelia During Laparoscopic Surgery With Neurologic Monitoring: A Case Report.A&A practice · 2025Article
- Pcv-aCOInternational journal of general medicine · 2024Article
- Could trauma laparoscopy be the standard of care for hemodynamically stable patients? A retrospective analysis of 165 cases.Surgical endoscopy · 2023Article
- Non-Invasive Intracranial Pressure Monitoring.Journal of clinical medicine · 2023Review
- The effect of laparoscopy on intracranial pressure as measured by optic nerve sheath diameter: A review.The Canadian veterinary journal = La revue veterinaire canadienne · 2022Review
- Comparison of Optic Nerve Sheath Diameter (ONSD) in Low-Pressure Versus Normal Pressure Pneumoperitoneum in Laparoscopic Cholecystectomy: A Randomized Clinical Study.Medical journal of the Islamic Republic of Iran · 2022Article
- Optic nerve sheath diameter: present and future perspectives for neurologists and critical care physicians.Neurological sciences : official journal of the Italian Neurological Society and of the Italian Society of Clinical Neurophysiology · 2019Review
- Effect of sevoflurane, propofol and propofol with dexmedetomidine as maintenance agent on intracranial pressure in the Trendelenburg position during laparoscopic surgeries.Journal of anaesthesiology, clinical pharmacologyArticle
- Comparative evaluation of optic nerve sheath diameter in patients undergoing laparoscopic cholecystectomy using low and standard pressures of gas insufflations.Journal of anaesthesiology, clinical pharmacologyArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundLaparoscopic surgery involves the creation of a carbon dioxide (CO
methodsA computerized literature search was performed in August 2016 to identity prospective studies that measured ONSD to assess ICP changes during laparoscopic surgery. The primary outcome was the change in ONSD during the early (0-30 min) and late (30-120 min) periods after initiating pneumoperitoneum, compared with baseline values measured after anesthesia induction. Mean differences (MDs) with 95% confidence intervals [CIs] were calculated.
resultsNine observational studies and one randomized controlled trial, with a total of 460 subjects, were analyzed. Compared to the baseline value after anesthesia induction, significant increases in ONSD were observed in both the early period (MD 0.46, 95% CI 0.31-0.61, P < 0.001, I
conclusionsThe current meta-analysis revealed that ICP elevation during laparoscopy could be anticipated through a significant increase in the ONSD in the early (0-30 min) and late (30-120 min) periods during CO
Indexed as
Identifiers
What OpenQuestion holds
Registered trials