Evidence map›Paper›PMID 28631225›Full record

ArticleAuto- immunity highlights2017

Definition of the upper reference limit for thyroglobulin antibodies according to the National Academy of Clinical Biochemistry guidelines: comparison of eleven different automated methods.

F D'Aurizio, P Metus, A Ferrari, B Caruso, R Castello, D Villalta, A Steffan, K Gaspardo, F Pesente, N Bizzaro and 5 more

Open access · diamondAbstract read
In one paragraph

Article in Auto- immunity highlights, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed, 1 pooled it
1.2field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 1 synthesis or guideline pooled it, 28 citations in OpenAlex.

  1. Guideline
  2. Review
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors at 8 institutions in 1 country.

F D'AurizioClinical Pathology Institute, University Hospital, P.le S. Maria della Misericordia, 33100, Udine, Italy. federica.daurizio@asuiud.sanita.fvg.it.
P MetusClinical Pathology Laboratory, 'S. Maria degli Angeli' Hospital, Pordenone, Italy.
A FerrariClinical Pathology Laboratory, University Hospital, Verona, Italy.
B CarusoClinical Pathology Laboratory, University Hospital, Verona, Italy.
R CastelloGeneral Medicine and Endocrinology, University Hospital, Verona, Italy.
D VillaltaAllergology and Immunology, 'S. Maria degli Angeli' Hospital, Pordenone, Italy.
A SteffanOncological Clinical Pathology Laboratory, CRO, IRCCS, Aviano, Italy.
K GaspardoOncological Clinical Pathology Laboratory, CRO, IRCCS, Aviano, Italy.
F PesenteClinical Pathology Laboratory, 'S. Antonio Hospital', Tolmezzo, Italy.
N BizzaroClinical Pathology Laboratory, 'S. Antonio Hospital', Tolmezzo, Italy.
E TonuttiLaboratory of Immunopathology and Allergology, University Hospital, Udine, Italy.
S ValverdeLaboratory Medicine, 'Madonna della Navicella' Hospital, Chioggia (Ve), Italy.
C CosmaDepartment of Laboratory Medicine, University Hospital, Padua, Italy.
M PlebaniDepartment of Laboratory Medicine, University Hospital, Padua, Italy.
R TozzoliClinical Pathology Laboratory, 'S. Maria degli Angeli' Hospital, Pordenone, Italy.
Azienda Ospedaliera Santa Maria Degli Angeli · ITUniversity of Verona · ITOspedale Sant Antonio · ITUniversity of Padua · ITCentro di Riferimento Oncologico · ITIstituti di Ricovero e Cura a Carattere Scientifico · ITOspedale Santa Maria della Misericordia di Udine · ITUniversity of Udine · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeIn the last two decades, thyroglobulin autoantibodies (TgAb) measurement has progressively switched from marker of thyroid autoimmunity to test associated with thyroglobulin (Tg) to verify the presence or absence of TgAb interference in the follow-up of patients with differentiated thyroid cancer. Of note, TgAb measurement is cumbersome: despite standardization against the International Reference Preparation MRC 65/93, several studies demonstrated high inter-method variability and wide variation in limits of detection and in reference intervals. Taking into account the above considerations, the main aim of the present study was the determination of TgAb upper reference limit (URL), according to the National Academy of Clinical Biochemistry guidelines, through the comparison of eleven commercial automated immunoassay platforms.

methodsThe sera of 120 healthy males, selected from a population survey in the province of Verona, Italy, were tested for TgAb concentration using eleven IMA applied on as many automated analyzers: AIA-2000 (AIA) and AIA-CL2400 (CL2), Tosoh Bioscience; Architect (ARC), Abbott Diagnostics; Advia Centaur XP (CEN) and Immulite 2000 XPi (IMM), Siemens Healthineers; Cobas 6000 (COB), Roche Diagnostics; Kryptor (KRY), Thermo Fisher Scientific BRAHMS, Liaison XL (LIA), Diasorin; Lumipulse G (LUM), Fujirebio; Maglumi 2000 Plus (MAG), Snibe and Phadia 250 (PHA), Phadia AB, Thermo Fisher Scientific. All assays were performed according to manufacturers' instructions in six different laboratories in Friuli-Venezia Giulia and Veneto regions of Italy [Lab 1 (AIA), Lab 2 (CL2), Lab 3 (ARC, COB and LUM), Lab 4 (CEN, IMM, KRY and MAG), Lab 5 (LIA) and Lab 6 (PHA)]. Since TgAb values were not normally distributed, the experimental URL (e-URL) was established at 97.5 percentile according to the non-parametric method.

resultsTgAb e-URLs showed a significant inter-method variability. Considering the same method, e-URL was much lower than that suggested by manufacturers (m-URL), except for ARC and MAG. Correlation and linear regression were unsatisfactory. Consequently, the agreement between methods was poor, with significant bias in Bland-Altman plot.

conclusionsDespite the efforts for harmonization, TgAb methods cannot be used interchangeably. Therefore, additional effort is required to improve analytical performance taking into consideration approved protocols and guidelines. Moreover, TgAb URL should be used with caution in the management of differentiated thyroid carcinoma patients since the presence and/or the degree of TgAb interference in Tg measurement has not yet been well defined.

Indexed as

Autoimmune thyroid diseaseHarmonizationImmunoassayThyroglobulin autoantibodiesUpper reference limit

Identifiers

PMID28631225
PMCPMC5476530
OpenAlexW2631196069

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked