Evidence map›Paper›PMID 28631190›Full record

ArticleEuropean spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society2017

Pedicle screw insertion accuracy in terms of breach and reposition using a new intraoperative cone beam computed tomography imaging technique and evaluation of the factors associated with these parameters of accuracy: a series of 695 screws.

Virginie Cordemans, Ludovic Kaminski, Xavier Banse, Bernard G Francq, Christine Detrembleur, Olivier Cartiaux

Abstract read
PubMed Publisher
In one paragraph

Article in European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
2.0field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 31 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Navigated percutaneous versus open pedicle screw implantation using intraoperative CT and robotic cone-beam CT imaging.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Virginie CordemansNeuro Musculo Skeletal Lab (NMSK), Institut de Recherche Expérimentale et Clinique, Université Catholique de Louvain-la-Neuve, UCL/IREC/CARS, Avenue Mounier 53, Box B1.53.07, 1200, Brussels, Belgium. virginie.cordemans@uclouvain.be.ORCID 0000-0003-1886-5398
Ludovic KaminskiService d'orthopédie et de traumatologie de l'appareil locomoteur, Cliniques universitaires Saint-Luc, Avenue Hippocrate 10, 1200, Brussels, Belgium.
Xavier BanseNeuro Musculo Skeletal Lab (NMSK), Institut de Recherche Expérimentale et Clinique, Université Catholique de Louvain-la-Neuve, UCL/IREC/CARS, Avenue Mounier 53, Box B1.53.07, 1200, Brussels, Belgium.
Bernard G FrancqInstitute of Statistics, Biostatistics and Actuarial sciences (ISBA), Université Catholique de Louvain-la-Neuve, voie du Roman Pays 34/L1.03.01, 1348, Louvain-la-Neuve, Belgium.
Christine DetrembleurNeuro Musculo Skeletal Lab (NMSK), Institut de Recherche Expérimentale et Clinique, Université Catholique de Louvain-la-Neuve, UCL/IREC/CARS, Avenue Mounier 53, Box B1.53.07, 1200, Brussels, Belgium.
Olivier CartiauxNeuro Musculo Skeletal Lab (NMSK), Institut de Recherche Expérimentale et Clinique, Université Catholique de Louvain-la-Neuve, UCL/IREC/CARS, Avenue Mounier 53, Box B1.53.07, 1200, Brussels, Belgium.
UCLouvain · BECliniques Universitaires Saint-Luc · BE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe goals of this study were to assess the accuracy of pedicle screw insertion using an intraoperative cone beam computed tomography (CBCT) system, and to analyze the factors potentially influencing this accuracy.

methodsSix hundred and ninety-five pedicle screws were inserted in 118 patients between October 2013 and March 2016. Screw insertion was performed using 2D-fluoroscopy or CBCT-based navigation. Accuracy was assessed in terms of breach and reposition. All the intraoperative CBCT scans, done after screw insertion, were reviewed to assess the accuracy of screw placement using two established classification systems: Gertzbein and Heary. Generalized linear mixed models were used to model the odds (95% CI) for a screw to lead to a breach according to the independent variables.

resultsThe breach rate was 11.7% using the Gertzbein classification and 15.4% using the Heary classification. Seventeen screws (2.4%) were repositioned intraoperatively. The only factor affecting statistically the odds to have a breach was the indication of surgery. The patients with non-degenerative disease had a significantly higher risk of breach than those with degenerative disease.

conclusionUse of intraoperative CBCT as 2D-fluoroscopy or coupled with a navigation system for pedicle screw insertion is accurate in terms of breach occurrence and reposition. However, these rates depend on the classification or grading system used. Use of a navigation system does not decrease the risk of breach significantly. And the risk of breach is higher in non-degenerative conditions (trauma, scoliosis, infection, and malignancy disease) than in degenerative diseases.

Indexed as

Cone-Beam Computed TomographySpinal FusionSurgery, Computer-AssistedHumansIntervertebral Disc DegenerationPedicle ScrewsRetrospective StudiesSpineAccuracyBreach detectionCone beam computed tomography (CBCT)Navigation systemPedicle screw insertionScrew reposition

Identifiers

PMID28631190
OpenAlexW2710352571

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.