Evidence map›Paper›PMID 28630342›Full record

ArticleProceedings of the National Academy of Sciences of the United States of America2017

Autoantibody profiling on a plasmonic nano-gold chip for the early detection of hypertensive heart disease.

Xiaoyang Li, Tatiana Kuznetsova, Nicholas Cauwenberghs, Matthew Wheeler, Holden Maecker, Joseph C Wu, Francois Haddad, Hongjie Dai

Open access · bronzeAbstract read
In one paragraph

Article in Proceedings of the National Academy of Sciences of the United States of America, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
1.1field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 37 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Review
  5. Review
  6. Article
  7. Nanomedicines for cardiovascular disease.Nature cardiovascular research · 2023
    Review
  8. Article
  9. Article
  10. Review
  11. Article
  12. Review
  13. Article
  14. Article
  15. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 2 countries.

Xiaoyang LiDepartment of Chemistry, Stanford University, Stanford, CA 94305.
Tatiana KuznetsovaResearch Unit Hypertension and Cardiovascular Epidemiology, Department of Cardiovascular Sciences, University of Leuven, Leuven 3000, Belgium.
Nicholas CauwenberghsResearch Unit Hypertension and Cardiovascular Epidemiology, Department of Cardiovascular Sciences, University of Leuven, Leuven 3000, Belgium.
Matthew WheelerStanford University School of Medicine, Stanford, CA 94305.
Holden MaeckerDepartment of Microbiology and Immunology, Stanford University School of Medicine, Stanford, CA 94305.
Joseph C WuStanford University School of Medicine, Stanford, CA 94305.
Francois HaddadStanford University School of Medicine, Stanford, CA 94305; fhaddad@stanford.edu hdai@stanford.edu.
Hongjie DaiDepartment of Chemistry, Stanford University, Stanford, CA 94305; fhaddad@stanford.edu hdai@stanford.edu.
Stanford University · USKU Leuven · BECardiovascular Institute of the South · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The role of autoimmunity in cardiovascular (CV) diseases has been increasingly recognized. Autoimmunity is most commonly examined by the levels of circulating autoantibodies in clinical practices. Measurement of autoantibodies remains, however, challenging because of the deficiency of reproducible, sensitive, and standardized assays. The lack of multiplexed assays also limits the potential to identify a CV-specific autoantibody profile. To overcome these challenges, we developed a nanotechnology-based plasmonic gold chip for autoantibody profiling. This approach allowed simultaneous detection of 10 CV autoantibodies targeting the structural myocardial proteins, the neurohormonal regulatory proteins, the vascular proteins, and the proteins associated with apoptosis and coagulation. Autoantibodies were measured in four groups of participants across the continuum of hypertensive heart diseases. We observed higher levels of all 10 CV autoantibodies in hypertensive subjects (

Indexed as

AgedAnnexin A5AutoantibodiesAutoimmunityCase-Control StudiesEchocardiographyFemaleGoldHeart DiseasesHeart FailureHumansHypertensionMaleMetal NanoparticlesMiddle AgedNanotechnologyAnnexin A5AutoantibodiesGoldReceptors, Adrenergic, beta-1Troponin Iautoantibodiesearly detectionheart failurehigh-sensitivity multiplexed assayhypertensive heart disease

Identifiers

PMID28630342
PMCPMC5502602
OpenAlexW2730265207

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.