ArticleAnnals of intensive care2017
A new global and comprehensive model for ICU ventilator performances evaluation.
Article in Annals of intensive care, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Monitoring the patient-ventilator asynchrony during non-invasive ventilation.Frontiers in medicine · 2022Pooled it
- Impact of CPAP and ventilator system resistance on respiratory effort in healthy volunteers.BMC pulmonary medicine · 2026Trial
- Bedside Assessment of PEEP-Induced Volume and Mechanical Power in Mechanically Ventilated Adults Without ARDS: A Post Hoc Analysis.Medical sciences (Basel, Switzerland) · 2026Article
- Respiratory therapists' perceptions of electrical impedance tomography in pediatric intensive care: A mixed methods implementation study.Canadian journal of respiratory therapy : CJRT = Revue canadienne de la therapie respiratoire : RCTR · 2026Article
- Transforming critical care: the digital revolution's impact on intensive care units.Frontiers in digital health · 2025Review
- Evaluation of the Puritan Bennett™ 980 Ventilator System Safety and Performance in the Real-World Setting.Medical devices (Auckland, N.Z.) · 2024Article
- Are all ventilators for NIV performing the same? A bench analysis.Journal of clinical monitoring and computing · 2023Article
- Article
- A Usability Study of 3 Radiotherapy Systems: A Comparative Evaluation Based on Expert Evaluation and User Experience.Medical science monitor : international medical journal of experimental and clinical research · 2019Article
- Comprehensive Evaluation of User Interface for Ventilators Based on Respiratory Therapists' Performance, Workload, and User Experience.Medical science monitor : international medical journal of experimental and clinical research · 2018Article
- Usability Study of the User-Interface of Intensive Care Ventilators Based on User Test and Eye-Tracking Signals.Medical science monitor : international medical journal of experimental and clinical research · 2018Article
- The usability of ventilator maintenance user interface: A comparative evaluation of user task performance, workload, and user experience.Science progressArticle
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThis study aimed to provide a new global and comprehensive evaluation of recent ICU ventilators taking into account both technical performances and ergonomics.
methodsSix recent ICU ventilators were evaluated. Technical performances were assessed under two FIO
resultsFew differences in terms of technical performance were observed between devices. Non-invasive ventilation modes had a huge influence on asynchrony occurrence. Using our global model, either objective tasks completion, psycho-cognitive scales and/or physiological measurements were able to depict significant differences in terms of devices' usability. The level of failure that was observed with some devices depicted the lack of adaptation of device's development to end users' requests.
conclusionsDespite similar technical performance, some ICU ventilators exhibit low ergonomics performance and a high risk of misusage.
Identifiers
What OpenQuestion holds
Registered trials