ArticlePloS one2017
Evaluation of the performance of Abbott m2000 and Roche COBAS Ampliprep/COBAS Taqman assays for HIV-1 viral load determination using dried blood spots and dried plasma spots in Kenya.
Article in PloS one, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 25 papers, 3 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
25 citing papers in PubMed, 3 syntheses or guidelines pooled it, 38 citations in OpenAlex.
- Detection of Viral Nucleic Acid in Specimens Spotted on Commercial Filter Papers: A Review and Meta-Analysis.Viruses · 2026Pooled it
- The performance of using dried blood spot specimens for HIV-1 viral load testing: A systematic review and meta-analysis.PLoS medicine · 2022Pooled it
- Diagnostic Accuracy of Dried Plasma Spot Specimens for HIV-1 Viral Load Testing: A Systematic Review and Meta-analysis.Journal of acquired immune deficiency syndromes (1999) · 2022Pooled it
- Current Landscape of Molecular Diagnostic Tests and Emerging Tools for Tuberculosis and Drug Resistance.Diagnostics (Basel, Switzerland) · 2026Review
- Brief Report: Undetectable HIV-1 Viral Load Among Virally Suppressed People Living With HIV: Implications for Undetectable Equals Untransmittable (U=U) in Resource-Limited Settings Using Dried Spot Testing.Journal of acquired immune deficiency syndromes (1999) · 2025Article
- Assessment of the performance of the plasma separation card for HIV-1 viral load monitoring in South Africa.Journal of clinical microbiology · 2024Article
- Revolutionizing HIV-1 Viral Load Monitoring in India: The Potential of Dried Blood Spot Analysis for Expanding Access and Improving Care.Healthcare (Basel, Switzerland) · 2024Review
- Biological Fluid Microsampling for Therapeutic Drug Monitoring: A Narrative Review.Biomedicines · 2023Review
- Virologic Nonsuppression Among Patients With HIV Newly Diagnosed With Cancer at Uganda Cancer Institute: A Cross-Sectional Study.JCO global oncology · 2023Article
- Microsampling tools for collecting, processing, and storing blood at the point-of-care.Bioengineering & translational medicine · 2023Review
- Assessment of HIV viral load monitoring in remote settings in Vietnam - comparing people who inject drugs to the other patients.PloS one · 2023Article
- Stability of HIV-1 Nucleic Acids in cobas Plasma Separation Card for Viral Load Measurement.American journal of clinical pathology · 2022Article
- Field evaluation of HIV-1 viral load monitoring in adults and children receiving antiretroviral treatment in Nigeria by dried blood spot testing with RealTime HIV-1 on m2000.Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology · 2021Article
- The Development of a Standardized Quality Assessment Material to Support XpertDiagnostics (Basel, Switzerland) · 2021Article
- Article
- Use of viral load to improve survey estimates of known HIV-positive status and antiretroviral treatment coverage.AIDS (London, England) · 2020Article
- Cost and Impact of Dried Blood Spot Versus Plasma Separation Card for Scale-up of Viral Load Testing in Resource-limited Settings.Clinical infectious diseases : an official publication of the Infectious Diseases Society of America · 2020Article
- Accurate HIV viral load measurement in primary health care settings using the cobas® plasma separation card.PloS one · 2020Article
- HIV RNA measurement in dried blood spots of HIV-infected patients in Thailand using Abbott m2000 system.PloS one · 2020Article
- Observational
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundRoutine HIV viral load testing is not widely accessible in most resource-limited settings, including Kenya. To increase access to viral load testing, alternative sample types like dried blood spots (DBS), which overcome the logistic barriers associated with plasma separation and cold chain shipment need to be considered and evaluated. The current study evaluated matched dried blood spots (DBS) and dried plasma spots (DPS) against plasma using the Abbott M 2000 (Abbott) and Roche Cobas Ampliprep/Cobas TaqMan (CAP/CTM) quantitative viral load assays in western Kenya.
methodsMatched plasma DBS and DPS were obtained from 200 HIV-1 infected antiretroviral treatment (ART)-experienced patients attending patient support centers in Western Kenya. Standard quantitative assay performance parameters with accompanying 95% confidence intervals (CI) were assessed at the assays lower detection limit (400cps/ml for CAP/CTM and 550cps/ml for Abbott) using SAS version 9.2. Receiver operating curves (ROC) were further used to assess viral-load thresholds with best assay performance (reference assay CAP/CTM plasma).
resultsUsing the Abbott test, the sensitivity and specificity, respectively, for DPS were (97.3%, [95%CI: 93.2-99.2] and 98.1% [95%CI: 89.7-100]) and those for DBS (93.9% [95%CI: 88.8-97.2] and 88.0% [95%CI: 82.2-92.4]). The correlation and agreement using paired plasma and DPS/DBS were strong, with r2 = 90.5 and rc = 68.1. The Bland-Altman relative percent change was 95.3 for DPS, (95%CI: 90.4-97.7) and 73.6 (95%CI: 51.6-86.5) for DBS. Using the CAP/CTM assay, the sensitivity for DBS was significantly higher compared to DPS (100.0% [95% CI: 97.6-100.0] vs. 94.7% [95%CI: 89.8-97.7]), while the specificity for DBS was lower: 4%, [95% CI: 0.4-13.7] compared to DPS: 94.0%, [95% CI: 83.5-98.7]. When compared under different clinical relevant thresholds, the accuracy for the Abbott assay was 95% at the 1000cps/ml cut-off with a sensitivity and specificity of 96.6% [95% CI 91.8-98.7] and 90.4% [95% CI 78.2-96.4] respectively. The optimum threshold was at 3000 cps/ml with an accuracy of 95.5%, sensitivity and specificity of 94.6% [95%CI 89.3-97.5] and 98.1% [95%CI 88.4-99.9]) respectively. The best threshold for CAP/CTM was at 4000 copies /mL, with 92.5% accuracy (sensitivity of 96.0% [95%CI 91.0-98.3] and specificity of 82.7% [95%CI 69.2-91.3]).
conclusionsThere was similar performance between matched DBS, DPS and plasma using the Abbott test, and good correlation for matched DPS and plasma using the CAPCTM test. The findings suggest that DBS and DPS may be reliably used as alternative specimens to plasma to measure HIV-1 VL using Abbott, and DPS may be reliably used with CAP/CTM in resource-limited settings.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.