Quantification of radiation dose reduction by reducing z-axis coverage in 320-detector coronary CT angiography.

David J Murphy, Abhishek Keraliya, Nathan Himes, Ayaz Aghayev, Ron Blankstein, Michael L Steigner

Abstract read
In one paragraph

Article in The British journal of radiology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

David J MurphyCardiovascular Imaging Program, Departments of Radiology and Medicine (Cardiovascular Division), Brigham and Women's Hospital and Harvard Medical School, Boston, MA, USA.
Abhishek KeraliyaCardiovascular Imaging Program, Departments of Radiology and Medicine (Cardiovascular Division), Brigham and Women's Hospital and Harvard Medical School, Boston, MA, USA.
Nathan HimesCardiovascular Imaging Program, Departments of Radiology and Medicine (Cardiovascular Division), Brigham and Women's Hospital and Harvard Medical School, Boston, MA, USA.
Ayaz AghayevCardiovascular Imaging Program, Departments of Radiology and Medicine (Cardiovascular Division), Brigham and Women's Hospital and Harvard Medical School, Boston, MA, USA.
Ron BlanksteinCardiovascular Imaging Program, Departments of Radiology and Medicine (Cardiovascular Division), Brigham and Women's Hospital and Harvard Medical School, Boston, MA, USA.
Michael L SteignerCardiovascular Imaging Program, Departments of Radiology and Medicine (Cardiovascular Division), Brigham and Women's Hospital and Harvard Medical School, Boston, MA, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo quantify the radiation dose reduction achievable by minimizing z-axis coverage in 320-detector coronary CT angiography (CCTA).

methodsWe retrospectively reviewed 130 CCTAs performed on 320-detector CT that offers up to 16 cm z-axis coverage (adjustable in 2-cm increments), allowing complete coverage of the heart in a single gantry rotation. For each CT, we obtained the radiation dose [CT dose index and dose-length product (DLP)], measured the z-axis field of view and measured the craniocaudal cardiac size (distance from the left main coronary artery to the cardiac apex). We calculated the radiation dose savings achievable by reducing the z-axis coverage to the minimum necessary to cover the heart using 320 × 0.5-mm (maximum 16 cm) and 256 × 0.5-mm (maximum 12.8 cm) detector collimations.

resultsResults are expressed as mean ± standard deviation. The mean craniocaudal cardiac size was 10.5 ± 1.0 cm, with 85% (n = 112) of CCTAs performed with 16 cm of z-axis coverage. The mean DLP was 417.6 ± 182.4 mGy cm, with the mean DLP saving achievable using the minimum z-axis coverage required to completely image the heart being 96.2 ± 47.4 mGy cm, an average dose reduction of 26.9 ± 7.0%. z-axis coverage of ≤12 cm was adequate for 92% and 12.8 cm for 98% of subjects.

conclusionUsing the minimal z-axis coverage to adequately image the heart is a simple step that can reduce the DLP in 320-detector CCTA by approximately 27%. z-axis coverage of ≤12 cm is adequate for 92%, 12.8 cm for 98% and 14 cm for 100% of patients undergoing CCTA. Advances in knowledge: Reducing z-axis coverage in 320-detector CCTA can reduce DLP by approximately 27%.

Indexed as

Radiation DosageComputed Tomography AngiographyCoronary AngiographyCoronary Artery DiseaseFemaleHumansMaleMiddle AgedRetrospective Studies

Identifiers

PMID28613933
PMCPMC5607480

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.