Evidence map›Paper›PMID 28612121›Full record

ArticleEuropean journal of applied physiology2017

Estimation of respiratory volume from thoracoabdominal breathing distances: comparison of two models of machine learning.

Rémy Dumond, Steven Gastinger, Hala Abdul Rahman, Alexis Le Faucheur, Patrice Quinton, Haitao Kang, Jacques Prioux

Registry-linked trialAbstract read
PubMed Publisher
In one paragraph

Article in European journal of applied physiology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03673189 (Sensors for HEalth Recording and Physical Activity Monitoring), which is not on this map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.4field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT03673189 nacompletednot on this mapstarted 2018, after this paper: background citation

Sensors for HEalth Recording and Physical Activity Monitoring

TypeinterventionalSponsorRennes University HospitalRan2018 to 2019Enrolled30ConditionsPhysical ActivityArmssensors
3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 25 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Rémy DumondLaboratoire Mouvement, Sport, Santé (EA 1274), Université de Rennes 2, Avenue Robert Schuman, 35170, Bruz, France. remy.dumond@gmail.com.ORCID 0000-0003-0924-0986
Steven GastingerLaboratoire Mouvement, Sport, Santé (EA 1274), Université de Rennes 2, Avenue Robert Schuman, 35170, Bruz, France.
Hala Abdul RahmanLaboratoire Mouvement, Sport, Santé (EA 1274), Université de Rennes 2, Avenue Robert Schuman, 35170, Bruz, France.
Alexis Le FaucheurLaboratoire Mouvement, Sport, Santé (EA 1274), Université de Rennes 2, Avenue Robert Schuman, 35170, Bruz, France.
Patrice QuintonLaboratoire Mouvement, Sport, Santé (EA 1274), Université de Rennes 2, Avenue Robert Schuman, 35170, Bruz, France.
Haitao KangYuewu Electronic Technology Co., Ltd, Room 1008, Building B, No. 2305, Zuchongzhi Road, Shanghai, 201203, China.
Jacques PriouxLaboratoire Mouvement, Sport, Santé (EA 1274), Université de Rennes 2, Avenue Robert Schuman, 35170, Bruz, France. jacques.prioux@ens-rennes.fr.
Université Rennes 2 · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe purposes of this study were to both improve the accuracy of respiratory volume (V) estimates using the respiratory magnetometer plethysmography (RMP) technique and facilitate the use of this technique.

methodWe compared two models of machine learning (ML) for estimating [Formula: see text]: a linear model (multiple linear regression-MLR) and a nonlinear model (artificial neural network-ANN), and we used cross-validation to validate these models. Fourteen healthy adults, aged [Formula: see text] years participated in the present study. The protocol was conducted in a laboratory test room. The anteroposterior displacements of the rib cage and abdomen, and the axial displacements of the chest wall and spine were measured using two pairs of magnetometers. [Formula: see text] was estimated from these four signals, and the respiratory volume was simultaneously measured using a spirometer ([Formula: see text]) under lying, sitting and standing conditions as well as various exercise conditions (working on computer, treadmill walking at 4 and 6 km[Formula: see text], treadmill running at 9 and 12  km [Formula: see text] and ergometer cycling at 90 and 110 W).

resultsThe results from the ANN model fitted the spirometer volume significantly better than those obtained through MLR. Considering all activities, the difference between [Formula: see text] and [Formula: see text] (bias) was higher for the MLR model ([Formula: see text] L) than for the ANN model ([Formula: see text] L).

conclusionOur results demonstrate that this new processing approach for RMP seems to be a valid tool for estimating V with sufficient accuracy during lying, sitting and standing and under various exercise conditions.

Indexed as

Models, BiologicalRespirationAdultFemaleHumansLung Volume MeasurementsMachine LearningMaleOxygen ConsumptionRespiratory MechanicsYoung AdultElectromagnetic coilsMachine learningPhysical activity conditionPulmonary volumeRest condition

Identifiers

PMID28612121
OpenAlexW2625260914

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.