ArticleBMJ case reports2017
Cardiac arrest following arteriovenous fistula manipulation: a cautionary note.
Article in BMJ case reports, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 1 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Arteriovenous fistulas can lead to a number of different chronic complications. We describe a case where a patient developed a thrombosis within her brachiobasilic arteriovenous fistula, which was manually manipulated in order to restore fistula flow. This resulted in a pulseless electrical activity cardiac arrest within a few minutes. After ten minutes of chest compressions and intubation, there was return of spontaneous circulation. No epinephrine was given nor shocks administered. Patient was extubated within minutes and was alert, orientated and haemodynamically stable. CT pulmonary angiogram showed extensive bilateral pulmonary emboli. Manual manipulation of the arteriovenous fistula lead to significant amounts of thrombus embolising to the pulmonary arteries, and resultant cardiac arrest due to circulatory compromise. Chest compressions likely dislodged these emboli, allowing circulation to recommence. We publish this as a cautionary note of a rare but potentially fatal complication.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.