Evidence map›Paper›PMID 28600383›Full record

ArticleBone & joint research2017

Validation of static and dynamic radiostereometric analysis of the knee joint using bone models from CT data.

K Stentz-Olesen, E T Nielsen, S De Raedt, P B Jørgensen, O G Sørensen, B L Kaptein, M S Andersen, M Stilling

Open access · goldAbstract read
In one paragraph

Article in Bone & joint research, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
3.0field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 19 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Reconstructing the anterolateral ligament does not decrease rotational knee laxity in ACL-reconstructed knees.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2017
    Article
  8. Article
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 2 countries.

K Stentz-OlesenOrthopaedic Research Group, Department of Orthopaedic Surgery, Aarhus University Hospital, Tage-Hansens Gade 2, Building 10A, Office 15, 8000 Aarhus C, Denmark.
E T NielsenOrthopaedic Research Group, Department of Orthopaedic Surgery, Aarhus University Hospital, Tage-Hansens Gade 2, Building 10A, Office 15, 8000 Aarhus C, Denmark.
S De RaedtNordisk Røntgen Teknik, Birkegårdsvej 16, 8361 Hesselager, Denmark.
P B JørgensenOrthopaedic Research Group, Department of Orthopaedic Surgery, Aarhus University Hospital, Tage-Hansens Gade 2, Building 9A, 8000 Aarhus C, Denmark.
O G SørensenOrthopaedic Research Group, Department of Orthopaedic Surgery, Aarhus University Hospital, Tage-Hansens Gade 2, Building 10A, Office 15, 8000 Aarhus C, Denmark.
B L KapteinBiomechanics and Imaging Group, Department of Orthopaedic Surgery, Leiden University Medical Center, Albinusdreef 2, 2333 ZA Leiden, The Netherland.
M S AndersenDepartment of Mechanical Engineering and Manufacturing, Aalborg University, Fibigerstræde 16, 9220 Aalborg East, Denmark.
M StillingOrthopaedic Research Group, Departments of Orthopaedic Surgery and Clinical Medicine, Aarhus University Hospital, University of Aarhus, Tage-Hansens Gade 2, Building 10A, 8000 Aarhus C, Denmark kasperstentz@gmail.com.
Aarhus University Hospital · DKAalborg University · DKLeiden University Medical Center · NLNovo Nordisk (Denmark) · DK

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesStatic radiostereometric analysis (RSA) using implanted markers is considered the most accurate system for the evaluation of prosthesis migration. By using CT bone models instead of markers, combined with a dynamic RSA system, a non-invasive measurement of joint movement is enabled. This method is more accurate than current 3D skin marker-based tracking systems. The purpose of this study was to evaluate the accuracy of the CT model method for measuring knee joint kinematics in static and dynamic RSA using the marker method as the benchmark.

methodsBone models were created from CT scans, and tantalum beads were implanted into the tibia and femur of eight human cadaver knees. Each specimen was secured in a fixture, static and dynamic stereoradiographs were recorded, and the bone models and marker models were fitted to the stereoradiographs.

resultsResults showed a mean difference between the two methods in all six degrees of freedom for static RSA to be within -0.10 mm/° and 0.08 mm/° with a 95% limit of agreement (LoA) ranging from ± 0.49 to 1.26. Dynamic RSA had a slightly larger range in mean difference of -0.23 mm/° to 0.16 mm/° with LoA ranging from ± 0.75 to 1.50.

conclusionsIn a laboratory-controlled setting, the CT model method combined with dynamic RSA may be an alternative to previous marker-based methods for kinematic analyses.

Indexed as

CT bone modelDynamicRadiostereometric analysis

Identifiers

PMID28600383
PMCPMC5492337
OpenAlexW2623155913

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.