Collimated superfine x-ray beam based x-ray luminescence computed tomography.

Wei Zhang, Dianwen Zhu, Michael Lun, Changqing Li

Abstract read
In one paragraph

Article in Journal of X-ray science and technology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Article
  2. Oxygenation imaging in deep tissue with X-Ray luminescence computed tomography (XLCT).Proceedings of SPIE--the International Society for Optical Engineering · 2023
    Article
  3. Article
  4. Article
  5. Article
  6. X-ray luminescence imaging for small animals.Proceedings of SPIE--the International Society for Optical Engineering · 2020
    Article
  7. High-resolution x-ray luminescence computed tomography.Proceedings of SPIE--the International Society for Optical Engineering · 2020
    Article
  8. Article
  9. Focused x-ray luminescence computed tomography: experimental studies.Proceedings of SPIE--the International Society for Optical Engineering · 2019
    Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Wei ZhangSchool of Engineering, University of California, Merced, Merced, CA, USA.
Dianwen ZhuSchool of Engineering, University of California, Merced, Merced, CA, USA.
Michael LunSchool of Engineering, University of California, Merced, Merced, CA, USA.
Changqing LiSchool of Engineering, University of California, Merced, Merced, CA, USA.

Funding

Microscopic X-ray Luminescence Computed TomographyR03EB022305 · NIBIB · UNIVERSITY OF CALIFORNIA, MERCED · PI LI, CHANGQING · 2016 to 2017
$137k
NIBIB NIH HHS R03 EB022305
6 · The paper itself

Abstract

X-ray luminescence computed tomography (XLCT) is a hybrid imaging modality with the potential to achieve a spatial resolution up to several hundred micrometers for targets embedded in turbid media with a depth larger than several millimeters. In this paper, we report a high spatial resolution XLCT imaging system with a collimated superfine x-ray beam in imaging the deeply embedded targets. A collimator with a 100 micrometer pinhole was mounted in the front of a powerful x-ray tube to generate a superfine x-ray pencil beam with a beam diameter of 0.175 mm. For the phantom experiment of four capillary targets with an edge-to-edge distance of 400 micrometers, we were able to reconstruct the targets in a depth of 5 mm successfully, which were validated with microCT images. We have further investigated the effect of different x-ray beam diameters on the reconstructed XLCT images with numerical simulations. Our results indicate that XLCT has the ability to image successfully multiple deeply embedded targets when the collimated x-ray beam diameter is less than or equal to the target edge-to-edge distance. Our numerical simulations also demonstrate that XLCT can achieve a spatial resolution of 200 micrometers for targets embedded at a depth of 5 mm if the scanning beam has a diameter of 100 micrometers.

Indexed as

AlgorithmsImage Processing, Computer-AssistedLuminescencePhantoms, ImagingTomography, X-Ray ComputedX-Raysmedical optics instrumentationtomographyturbid mediaX-ray imaging

Identifiers

PMID28598861
PMCPMC6188660

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.