ArticleExperimental and therapeutic medicine2017
The value of Sonoclot detection technology to guide the clinical medication of the perioperative anticoagulation and antiplatelet therapy in patients with acute myocardial infarction undergoing emergent PCI.
Article in Experimental and therapeutic medicine, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06013020 (Safety and Efficacy of Century Clot-Guided Prophylactic Rivaroxaban Therapy for Post ST-Segment Elevation Myocardial Infarction Complicating Left Ventricular Thrombus Compared With Conventional Antiplatelet Therapy), which is not on this map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Safety and Efficacy of Century Clot-Guided Prophylactic Rivaroxaban Therapy for Post ST-Segment Elevation Myocardial Infarction Complicating Left Ventricular Thrombus Compared With Conventional Antiplatelet Therapy
Who cites it
4 citing papers in PubMed, 7 citations in OpenAlex.
- Model construction and application for predicting pre-eclampsia by Sonoclot coagulation analyzer.Non-coding RNA research · 2024Article
- Bleeding risk assessment in immune thrombocytopenia.Annals of hematology · 2023Article
- Sonoclot's usefulness in prediction of cardiopulmonary arrest prognosis: A proof of concept study.Open medicine (Warsaw, Poland) · 2022Article
- Sonoclot Signature Analysis: A New Point-of-Care Testing Method for Defining Heat Stroke-Induced Coagulopathy.International journal of general medicine · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The value of Sonoclot detection technology to guide the clinical medication of the perioperative anticoagulation and antiplatelet therapy in patients with acute myocardial infarction (AMI) undergoing emergent percutaneous coronary intervention (PCI) was estimated. One hundred and twenty-eight patients were randomly divided into control group and observation group with 64 cases in each group. Control group adopted routine blood coagulation indexes, including prothrombin time, activated partial thromboplastin time, fibrinogen and plasma thrombin time, platelet count and platelet aggregation turbidity analysis; observation group adopted Sonoclot detection technology, including activated clotting time, coagulation rate and platelet function. Anticoagulant therapy selected was of low molecular weight heparin calcium perioperatively, intraoperative unfractionated heparin, and clopidogrel (75 mg) combined with aspirin enteric-coated tablets (100 mg) as antiplatelet drugs. The therapy was administered in accordance with blood coagulation results. The blood coagulation time, postoperative creatine kinase isoenzyme MB, cardiac troponin I and B-type natriuretic peptide levels in the observation group are significantly lower than those in the control group (P<0.05) though the operating time and specifications of the stenting did not show any significant difference (P>0.05). The incidence of recurrent myocardial infarction, microembolism, acute and subacute thrombosis and bleeding events in the observation group are significantly lower than those in the control group (P<0.05). In the control group, there is no difference in the coagulation indexes of the patients with thrombosis events or bleeding events or no event (P>0.05). Whereas, in the observation group, there is significant difference in coagulation indexes of the patients with thrombosis events or bleeding events or no event (P<0.05). In conclusion, Sonoclot detection technology instructs emergent PCI treatment in AMI patients to shorten the detection time of blood coagulation, reduce the degree of myocardial injury, reduce the incidence of perioperative thrombosis and bleeding events. Furthermore, it has great value in guiding the clinical medication of anticoagulation and antiplatelet therapy.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.