Evidence map›Paper›PMID 28579743›Full record

ArticleClinical ophthalmology (Auckland, N.Z.)2017

Novel positioning sensor with real-time feedback for improved postoperative positioning: pilot study in control subjects.

Frank L Brodie, David A Ramirez, Sundar Pandian, Kelly Woo, Ashwin Balakrishna, Eugene De Juan, Hyuck Choo, Robert H Grubbs

Abstract read
In one paragraph

Article in Clinical ophthalmology (Auckland, N.Z.), 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Digital health and wearable devices for retinal disease monitoring.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2025
    Review
  2. Article
  3. Tracking postoperative head positioning in endothelial keratoplasty using a head positioning sensor.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2020
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Frank L BrodieDepartment of Ophthalmology, University of California San Francisco, San Francisco, CA, USA.
David A RamirezSchool of Medicine, University of California San Francisco, San Francisco, CA, USA.
Sundar PandianDepartment of Medical Engineering, California Institute of Technology, Pasadena, CA, USA.
Kelly WooDepartment of Medical Engineering, California Institute of Technology, Pasadena, CA, USA.
Ashwin BalakrishnaDepartment of Medical Engineering, California Institute of Technology, Pasadena, CA, USA.
Eugene De JuanDepartment of Ophthalmology, University of California San Francisco, San Francisco, CA, USA.
Hyuck ChooDepartment of Medical Engineering, California Institute of Technology, Pasadena, CA, USA.
Robert H GrubbsDepartment of Medical Engineering, California Institute of Technology, Pasadena, CA, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionRepair of retinal detachment frequently requires use of intraocular gas. Patients are instructed to position themselves postoperatively to appose the intraocular bubble to the retinal break(s). We developed a novel wearable wireless positioning sensor, which provides real-time audiovisual feedback on the accuracy of positioning.

methodsEight healthy volunteers wore the wireless sensor for 3 hours while instructed to maintain their head tilted toward the 2 o'clock meridian with no audiovisual feedback. Positioning accuracy was recorded. The subjects repeated the experiment for 3 hours with the audiovisual feedback enabled.

resultsWith no audiovisual feedback, the percentage of time greater than 10° out of position varied from 8.9% to 93.9%. With audiovisual feedback enabled, these percentages ranged from 9.4% to 65%. Three subjects showed significant improvement in their time out of position (

conclusionThe novel positioning sensor showed improved positioning compliance in half of the healthy volunteers during our short pilot study. Other subjects derived little benefit from the feedback. The causes for this observation are unclear. However, given the significant improvement as a group, this new technology could be beneficial to patients who struggle with postoperative positioning.

Indexed as

deviceintraocular gasmacular holepneumatic retinopexypostoperative positioningretinal detachmentvitrectomy

Identifiers

PMID28579743
PMCPMC5449164

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked