ArticleJournal of applied clinical medical physics2017
Validation of a method for in vivo 3D dose reconstruction in SBRT using a new transmission detector.
Article in Journal of applied clinical medical physics, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 14 citations in OpenAlex.
- Dosimetric verification of stereotactic body radiotherapy treatment plan via ArcCHECK-3DVH system.Zhong nan da xue xue bao. Yi xue ban = Journal of Central South University. Medical sciences · 2021Article
- Validation of new transmission detector transmission factors for online dosimetry: an experimental study.Radiation oncology (London, England) · 2018Article
- Commissioning and validation of fluence-based 3D VMAT dose reconstruction system using new transmission detector.Radiological physics and technology · 2018Article
- Validation of Dolphin dosimetry in three dimensional patient-specific quality assurance programme.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation OncologyArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Stereotactic body radiation therapy (SBRT) involves the delivery of substantially larger doses over fewer fractions than conventional therapy. Therefore, SBRT treatments will strongly benefit patients using vivo patient dose verification, because the impact of the fraction is large. For in vivo measurements, a commercially available quality assurance (QA) system is the COMPASS system (IBA Dosimetry, Germany). For measurements, the system uses a new transmission detector (Dolphin, IBA Dosimetry). In this study, we evaluated the method for in vivo 3D dose reconstruction for SBRT using this new transmission detector. We confirmed the accuracy of COMPASS with Dolphin for SBRT using multi leaf collimator (MLC) test patterns and clinical SBRT cases. We compared the results between the COMPASS, the treatment planning system, the Kodak EDR2 film, and the Monte Carlo (MC) calculations. MLC test patterns were set up to investigate various aspects of dose reconstruction for SBRT: (a) simple open fields (2 × 2-10 × 10 cm
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.