ArticleJournal of clinical monitoring and computing2018
Uncontrolled delivery of liquid volatile anaesthetic when using the anaesthetic conserving device.
Article in Journal of clinical monitoring and computing, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 2 citations in OpenAlex.
- EOY summary 2018.Journal of clinical monitoring and computing · 2019Review
- Sedation with inhaled agents in the ICU: what are we waiting for?Journal of clinical monitoring and computing · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
During patient sedation with liquid volatile anaesthetic, some problems may occur through a process called auto-pumping, defined as an expansion of bubbles inside the syringe, which can lead to uncontrolled anaesthetic delivery. The study examined how the temperature of liquid volatile anaesthetics (sevoflurane and isoflurane) and the presence of gas bubbles in the syringe affect the occurrence of auto-pumping when using the anaesthetic conserving device (ACD, AnaConDa™, Sedana Medical, Uppsala, Sweden). Four different circumstances for each volatile anaesthetic were tested with a bench study: volatile anaesthetic at room temperature or precooled with and without the presence of gas bubbles in the syringe. Liquid volatile anaesthetic was infused into the ACD via a syringe pump at a fixed rate and heated gradually until the temperature of the syringe surface reached 50 °C. A main-stream gas monitor was used to measure the expired fraction of volatile anaesthetic (F
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.