Evidence map›Paper›PMID 28567102›Full record

ReviewUltrasound (Leeds, England)2017

Neonatal respiratory distress syndrome: Chest X-ray or lung ultrasound? A systematic review.

Matthew Hiles, Anne-Marie Culpan, Catriona Watts, Theresa Munyombwe, Stephen Wolstenhulme

Abstract readReview
In one paragraph

Review in Ultrasound (Leeds, England), 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 41 papers, 5 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
41citing papers in PubMed, 5 pooled it
7.5field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

41 citing papers in PubMed, 5 syntheses or guidelines pooled it, 118 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Pooled it
  5. [Guideline on lung ultrasound to diagnose pulmonary diseases in newborn infants].Zhongguo dang dai er ke za zhi = Chinese journal of contemporary pediatrics · 2019
    Guideline
  6. Observational
  7. Observational
  8. Observational
  9. Review
  10. Article
  11. Article
  12. Review
  13. Review
  14. Article
  15. Review
  16. RDS-NExT workshop: consensus statements for the use of surfactant in preterm neonates with RDS.Journal of perinatology : official journal of the California Perinatal Association · 2023
    Article
  17. Review
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Matthew HilesDepartment of Radiology, Hull and East Yorkshire NHS Trust, Ultrasound Department, UK.
Anne-Marie CulpanDivision of Biomedical Imaging, Faculty of Medicine & Health, University of Leeds, UK.
Catriona WattsDepartment of Radiology, Hull and East Yorkshire NHS Trust, Ultrasound Department, UK.
Theresa MunyombweDivision of Epidemiology and Biostatistics, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, UK.
Stephen WolstenhulmeLeeds Teaching Hospitals NHS Trust, St James's University Hospital, UK.
Hull and East Yorkshire Hospitals NHS Trust · GBUniversity of Leeds · GBSt James's University Hospital · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND AND

aimNeonatal respiratory distress syndrome is a leading cause of morbidity in preterm new-born babies (<37 weeks gestation age). The current diagnostic reference standard includes clinical testing and chest radiography with associated exposure to ionising radiation. The aim of this review was to compare the diagnostic accuracy of lung ultrasound against the reference standard in symptomatic neonates of ≤42 weeks gestation age.

methodsA systematic search of literature published between 1990 and 2016 identified 803 potentially relevant studies. Six studies met the review inclusion criteria and were retrieved for analysis. Quality assessment was performed before data extraction and meta-analysis.

resultsFour prospective cohort studies and two case control studies included 480 neonates. All studies were of moderate methodological quality although heterogeneity was evident across the studies. The pooled sensitivity and specificity of lung ultrasound were 97% (95% confidence interval [CI] 94-99%) and 91% (CI: 86-95%) respectively. False positive diagnoses were made in 16 cases due to pneumonia (n = 8), transient tachypnoea (n = 3), pneumothorax (n = 1) and meconium aspiration syndrome (n = 1); the diagnoses of the remaining three false positive results were not specified. False negatives diagnoses occurred in nine cases, only two were specified as air-leak syndromes.

conclusionsLung ultrasound was highly sensitive for the detection of neonatal respiratory distress syndrome although there is potential to miss co-morbid air-leak syndromes. Further research into lung ultrasound diagnostic accuracy for neonatal air-leak syndrome and economic modelling for service integration is required before lung ultrasound can replace chest radiography as the imaging component of the reference standard.

Indexed as

chest X-raydiagnosislung ultrasoundNeonatal respiratory distress syndrome

Identifiers

PMID28567102
PMCPMC5438053
OpenAlexW2582270020

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.