The influence of cement thickness on stem subsidence and cement creep in a collarless polished tapered stem: When are thick cement mantles detrimental?

E Takahashi, A Kaneuji, R Tsuda, Y Numata, T Ichiseki, K Fukui, N Kawahara

Abstract read
In one paragraph

Article in Bone & joint research, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

E TakahashiDepartment of Orthopaedic Surgery, Kanazawa Medical University, Daigaku, Uchinada-machi, Kahoku-gun, Ishikawa 920-0293, Japan.
A KaneujiDepartment of Orthopaedic Surgery, Kanazawa Medical University, Daigaku, Uchinada-machi, Kahoku-gun, Ishikawa 920-0293, Japan kaneuji@kanazawa-med.ac.jp.
R TsudaDepartment of Orthopaedic Surgery, Kanazawa Medical University, Daigaku, Uchinada-machi, Kahoku-gun, Ishikawa 920-0293, Japan.
Y NumataDepartment of Orthopaedic Surgery, Kanazawa Medical University, Daigaku, Uchinada-machi, Kahoku-gun, Ishikawa 920-0293, Japan.
T IchisekiDepartment of Orthopaedic Surgery, Kanazawa Medical University, Daigaku, Uchinada-machi, Kahoku-gun, Ishikawa 920-0293, Japan.
K FukuiDepartment of Orthopaedic Surgery, Kanazawa Medical University, Daigaku, Uchinada-machi, Kahoku-gun, Ishikawa 920-0293, Japan.
N KawaharaDepartment of Orthopaedic Surgery, Kanazawa Medical University, Daigaku, Uchinada-machi, Kahoku-gun, Ishikawa 920-0293, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesFavourable results for collarless polished tapered stems have been reported, and cement creep due to taper slip may be a contributing factor. However, the ideal cement thickness around polished stems remains unknown. We investigated the influence of cement thickness on stem subsidence and cement creep.

methodsWe cemented six collarless polished tapered (CPT) stems (two stems each of small, medium and large sizes) into composite femurs that had been reamed with a large CPT rasp to achieve various thicknesses of the cement mantle. Two or three tantalum balls were implanted in the proximal cement in each femur. A cyclic loading test was then performed for each stem. The migration of the balls was measured three-dimensionally, using a micro-computed tomography (CT) scanner, before and after loading. A digital displacement gauge was positioned at the stem shoulder, and stem subsidence was measured continuously by the gauge. Final stem subsidence was measured at the balls at the end of each stem.

resultsA strong positive correlation was observed between mean cement thickness and stem subsidence in the CT slices on the balls. In the small stems, the balls moved downward to almost the same extent as the stem. There was a significant negative correlation between cement thickness and the horizontal:downward ratio of ball movement.

conclusionCollarless polished tapered stems with thicker cement mantles resulted in greater subsidence of both stem and cement. This suggests that excessive thickness of the cement mantle may interfere with effective radial cement creep.

Indexed as

Cement thicknessPolished tapered stemTotal hip arthroplasty

Identifiers

PMID28566327
PMCPMC5457643