Evidence map›Paper›PMID 28566326›Full record

ArticleBone & joint research2017

Retrieval analysis of metal and ceramic femoral heads on a single CoCr stem design.

A Di Laura, H Hothi, J Henckel, I Swiatkowska, M H L Liow, Y-M Kwon, J A Skinner, A J Hart

Abstract read
In one paragraph

Article in Bone & joint research, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Retrieval Findings of Recalled Dual-Taper Hips.The Journal of bone and joint surgery. American volume · 2018
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

A Di LauraInstitute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, Middlesex, HA7 4LP, UK anna.laura.14@ucl.ac.uk.
H HothiInstitute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, Middlesex, HA7 4LP, UK.
J HenckelInstitute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, Middlesex, HA7 4LP, UK.
I SwiatkowskaInstitute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, Middlesex, HA7 4LP, UK.
M H L LiowDepartment of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, USA.
Y-M KwonDepartment of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, USA.
J A SkinnerInstitute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, Middlesex, HA7 4LP, UK.
A J HartInstitute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, Middlesex, HA7 4LP, UK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThe use of ceramic femoral heads in total hip arthroplasty (THA) has increased due to their proven low bearing wear characteristics. Ceramic femoral heads are also thought to reduce wear and corrosion at the head-stem junction with titanium (Ti) stems when compared with metal heads. We sought to evaluate taper damage of ceramic compared with metal heads when paired with cobalt chromium (CoCr) alloy stems in a single stem design.

methodsThis retrieval study involved 48 total hip arthroplasties (THAs) with CoCr V40 trunnions paired with either CoCr (n = 21) or ceramic (n = 27) heads. The taper junction of all hips was evaluated for fretting/corrosion damage and volumetric material loss using a roundness-measuring machine. We used linear regression analysis to investigate taper damage differences after adjusting for potential confounding variables.

resultsWe measured median taper material loss rates of 0.210 mm

conclusionsMetal heads did not increase taper damage on CoCr trunnions compared with ceramic heads from the same hip design. The amount of material released at the taper junctions was very low when compared with available data regarding CoCr/Ti coupling in metal-on-metal bearings.

Indexed as

Ceramic femoral headsHip prosthesesMetal femoral heads

Identifiers

PMID28566326
PMCPMC5457640

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.