ArticleExperimental and therapeutic medicine2017

Comparison of the iCare rebound tonometer and the Goldmann applanation tonometer.

Feng Gao, Xu Liu, Qing Zhao, Yingzhe Pan

Open access · diamondAbstract read
In one paragraph

Article in Experimental and therapeutic medicine, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers.

0numbers the graph read from it
0cells of the map it votes in
24citing papers in PubMed
3.6field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

24 citing papers in PubMed, 61 citations in OpenAlex.

  1. Sensitivity of the iFalconBMC veterinary research · 2026
    Article
  2. Validation of a New Handheld Automated Fixed-Force Applanation Tonometer.Translational vision science & technology · 2026
    Article
  3. Observational
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Updates on the Diagnosis and Management of Glaucoma.Mayo Clinic proceedings. Innovations, quality & outcomes · 2022
    Review
  12. Article
  13. Article
  14. Review
  15. Review
  16. Article
  17. Article
  18. Agreement and repeatability of Icare ic100 tonometer.Indian journal of ophthalmology · 2020
    Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Feng GaoDepartment of Ophthalmology, The First People's Hospital of Xiangyang, Hubei University of Medicine, Xiangyang, Hubei 441000, P.R. China.
Xu LiuDepartment of Ophthalmology, The First People's Hospital of Xiangyang, Hubei University of Medicine, Xiangyang, Hubei 441000, P.R. China.
Qing ZhaoDepartment of Ophthalmology, The First People's Hospital of Xiangyang, Hubei University of Medicine, Xiangyang, Hubei 441000, P.R. China.
Yingzhe PanDepartment of Ophthalmology, The First People's Hospital of Xiangyang, Hubei University of Medicine, Xiangyang, Hubei 441000, P.R. China.
Hubei University of Medicine · CNXiang Yang No.1 People's Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Tonometry is a fundamental procedure in routine ophthalmologic examination. Although regarded as the reference standard, the Goldmann applanation tonometer (GAT) has its limitations. A new portable alternative to the GAT is the iCare rebound tonometer (RT). The aim of the present study was to compare the intraocular pressure (IOP) results obtained using the RT and GAT and then correlate the results with the central corneal thickness (CCT). Moreover, the tolerability and safety of the RT were evaluated. The IOP of 336 patients (672 eyes) was determined by the RT and GAT. The patients were divided into three groups (group A, 7-15 mmHg, n=74; group B, 16-22 mmHg, n=218; and group C, 23-50 mmHg, n=44), based on the GAT IOP readings. Pachymetry and slit lamp inspection were also performed. To establish an agreement between the devices, a Bland-Altman analysis and paired t-test were performed. The correlation between CCT and IOP readings obtained by the two devices were assessed using linear regression correlation analysis. The mean IOP values of the RT and the GAT were 18.30±5.10 and 18.52±4.46 mmHg, respectively. There were no significant differences between them (t=-1.31, P=0.19). The 95% confidence interval of the differences between the two devices was -5.80-6.24 mmHg. The RT readings are correlated well with those of GAT (r=0.806, P=0.001). However, the RT measurements were significantly (t=-2.84, P=0.007) lower (-1.66±3.87 mmHg) than those obtained with GAT when GAT ≥23 mmHg. Both the RT (r=0.390, P=0.001) and the GAT (r=0.191, P=0.001) showed positive correlations with CCT. The IOP measurement with RT was well tolerated. None of the corneal epithelial defects was detected and all subjects denied discomfort. The RT is well tolerated and safe, and can be considered a reliable alternative to GAT for patients in a low to moderate IOP range. However, in patients with high IOP values, the measurements obtained with RT did not correlate well with those obtained by GAT. The RT readings are influenced more by CCT compared to GAT.

Indexed as

central corneal thicknessGoldmann applanation tonometryiCare rebound tonometerintraocular pressure

Identifiers

PMID28565785
PMCPMC5443276
OpenAlexW2590819978

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.