ArticleExperimental and therapeutic medicine2017
Comparison of the iCare rebound tonometer and the Goldmann applanation tonometer.
Article in Experimental and therapeutic medicine, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
24 citing papers in PubMed, 61 citations in OpenAlex.
- Sensitivity of the iFalconBMC veterinary research · 2026Article
- Validation of a New Handheld Automated Fixed-Force Applanation Tonometer.Translational vision science & technology · 2026Article
- Comparison of portable devices with standard glaucoma diagnostic testing for the detection of glaucoma for the purposes of glaucoma case finding in low-and middle- income countries.Eye (London, England) · 2026Observational
- Directional drift in biologically meaningful vector planes: A proposed geometric framework for early detection of subthreshold disease.PloS one · 2026Article
- Clinical Validation of M-TONX: A Novel Combo Rebound Tonometer and Pachymeter.Translational vision science & technology · 2024Article
- Comparison of Intraocular Pressure Measurements Using Three Different Methods (Goldmann Applanation Tonometry (GAT), Corvis ST, and iCare) Following Penetrating Keratoplasty.Journal of clinical medicine · 2024Article
- The relationship between intraocular pressure and glaucoma: An evolving concept.Progress in retinal and eye research · 2024Review
- A comparison of iCare and Goldmann applanation tonometry measurements during the COVID-19 pandemic: a retrospective study.International ophthalmology · 2024Article
- Easyton® transpalpebral versus Perkins applanation tonometry in different populations.International ophthalmology · 2023Article
- Outcomes of the Icare Rebound Tonometer versus the Gold Standard Tonometer in Measuring Intraocular Pressure among Mzuzu University Students, Malawi.Rwanda journal of medicine and health sciences · 2023Article
- Updates on the Diagnosis and Management of Glaucoma.Mayo Clinic proceedings. Innovations, quality & outcomes · 2022Review
- Intraocular pressure screening during high-volume cataract surgery outreach in Ethiopia.BMC ophthalmology · 2022Article
- Comparison of intraocular pressure readings with Perkins, Tonopen, iCare 200, and iCare Home to manometry in cadaveric eyes.International journal of ophthalmology · 2022Article
- How to Measure Intraocular Pressure: An Updated Review of Various Tonometers.Journal of clinical medicine · 2021Review
- Telehealth and Screening Strategies in the Diagnosis and Management of Glaucoma.Journal of clinical medicine · 2021Review
- Integrating Telemedicine Services in Ophthalmology: Evaluating Patient Interest and Perceived Benefits.Patient preference and adherence · 2021Article
- The Effect of Corneal Thickness, Densitometry and Curvature on Intraocular Pressure Measurements Obtained by Applanation, Rebound and Dynamic Contour Tonometry.Vision (Basel, Switzerland) · 2020Article
- Agreement and repeatability of Icare ic100 tonometer.Indian journal of ophthalmology · 2020Article
- A comparison of three different tonometric methods in the measurement of intraocular pressure in the pediatric age group.International ophthalmology · 2020Article
- Error in measurement of intraocular pressure with the Icare and IcarePRO.International ophthalmology · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Tonometry is a fundamental procedure in routine ophthalmologic examination. Although regarded as the reference standard, the Goldmann applanation tonometer (GAT) has its limitations. A new portable alternative to the GAT is the iCare rebound tonometer (RT). The aim of the present study was to compare the intraocular pressure (IOP) results obtained using the RT and GAT and then correlate the results with the central corneal thickness (CCT). Moreover, the tolerability and safety of the RT were evaluated. The IOP of 336 patients (672 eyes) was determined by the RT and GAT. The patients were divided into three groups (group A, 7-15 mmHg, n=74; group B, 16-22 mmHg, n=218; and group C, 23-50 mmHg, n=44), based on the GAT IOP readings. Pachymetry and slit lamp inspection were also performed. To establish an agreement between the devices, a Bland-Altman analysis and paired t-test were performed. The correlation between CCT and IOP readings obtained by the two devices were assessed using linear regression correlation analysis. The mean IOP values of the RT and the GAT were 18.30±5.10 and 18.52±4.46 mmHg, respectively. There were no significant differences between them (t=-1.31, P=0.19). The 95% confidence interval of the differences between the two devices was -5.80-6.24 mmHg. The RT readings are correlated well with those of GAT (r=0.806, P=0.001). However, the RT measurements were significantly (t=-2.84, P=0.007) lower (-1.66±3.87 mmHg) than those obtained with GAT when GAT ≥23 mmHg. Both the RT (r=0.390, P=0.001) and the GAT (r=0.191, P=0.001) showed positive correlations with CCT. The IOP measurement with RT was well tolerated. None of the corneal epithelial defects was detected and all subjects denied discomfort. The RT is well tolerated and safe, and can be considered a reliable alternative to GAT for patients in a low to moderate IOP range. However, in patients with high IOP values, the measurements obtained with RT did not correlate well with those obtained by GAT. The RT readings are influenced more by CCT compared to GAT.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.