Evidence map›Paper›PMID 28560037›Full record

ArticleMultidisciplinary respiratory medicine2017

Instant velocity and consistency of emitted cloud change by the different levels of canister filling with Metered Dose Inhalers (MDIs), but not with Soft Mist Inhalers (SMIs): a bench study.

Roberto W Dal Negro, Pietro Longo, Orestepaolo Villanis Ziani, Luca Bonadiman, Paola Turco

Abstract read
In one paragraph

Article in Multidisciplinary respiratory medicine, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Usability of inhaler devices: a parameter currently misused.Multidisciplinary respiratory medicine · 2024
    Article
  2. Article
  3. Article
  4. Choosing the right inhaler for your asthma or COPD patient.Therapeutics and clinical risk management · 2019
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Roberto W Dal NegroNational Centre for Respiratory Pharmacoeconomics & Pharmacoepidemiology - CESFAR, Verona, Italy.
Pietro LongoNational Centre for Respiratory Pharmacoeconomics & Pharmacoepidemiology - CESFAR, Verona, Italy.
Orestepaolo Villanis ZianiNational Centre for Respiratory Pharmacoeconomics & Pharmacoepidemiology - CESFAR, Verona, Italy.
Luca BonadimanNational Centre for Respiratory Pharmacoeconomics & Pharmacoepidemiology - CESFAR, Verona, Italy.
Paola TurcoResearch & Clinical Governance, Verona, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundInhalation is the preferred route for respiratory drug delivery, but several factors contribute to the variability of the respirable dose fraction. Instant velocity and the dynamic characteristics of the droplet cloud represent crucial factors. Aim was to measure and compare the instant velocity and the consistency of emitted cloud from five different MDIs (A - Salbutamol sulphate 100mcg, GSK; B - Salbutamol sulphate 100mcg, Valeas; C - Salmeterol xinafoate/Fluticasone propionate 25/125mcg, GSK; D - Formoterol fumarate/Bechlomethasone propionate 6/100mcg, Chiesi; E - Formoterol fumarate/Fluticasone dipropionate 5/125mcg, Mundipharma) and one SMI (Tiotropium bromide 5mcg, Boehringer Ingelheim), at different distance from the nozzle and canister filling.

methodsMeasurements were made at 90, 50, and 10% of canister filling, and at 5, 10, and 20 cm from the nozzle, for a total of 972 puffs. A high speed video photography protocol was adopted and high speed cameras (1.200 frames/sec.) were used. Data were acquired by means of specialized softwares. Temperature, humidity, and vibrations occurrence were strictly controlled during measurements. Statistics: Anova and

resultsMDIs generated different Instant velocities: MDI B generated the highest, while MDI A the lowest. As expected, velocity decreased in proportion to the distance from the nozzle. Except with MDI C, instant velocity decreased significantly over the first 50% of canister emptying, but dropped by >33% at 90% of emptying with all other MDIs ( DISCUSSION AND

conclusionsMDIs are characterized by a substantial variability in both their instant velocity and consistency of the emitted cloud at different levels of canister filling. SMI generates a much slower soft mist cloud which is constantly homogeneous and independent of canister emptying. These peculiarities assessed at bench are suggesting a higher dose consistency and a much more effective therapeutic performance also in real life.

Indexed as

Dose consistencyInstant velocityMDIsSMIVariability

Identifiers

PMID28560037
PMCPMC5447303

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.