Posterior Lumbar Interbody Fusion with Interspinous Fastener Provides Comparable Clinical Outcome and Fusion Rate to Pedicle Screws.

Wei-Min Huang, Xing-Ming Yu, Xiao-Duo Xu, Ruo-Xian Song, Li-Li Yu, Xiu-Chun Yu

Open access · bronzeAbstract readRandomized Controlled Trial
In one paragraph

Trial report in Orthopaedic surgery, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact, top 93% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Wei-Min HuangDepartment of Orthopaedics, General Hospital of Jinan Military Commanding Region, Jinan, China.
Xing-Ming YuPostgraduate Training Base in General Hospital of Jinan Military Command, Liaoning Medical University, Jinzhou, China.
Xiao-Duo XuDepartment of Orthopaedics, General Hospital of Jinan Military Commanding Region, Jinan, China.
Ruo-Xian SongDepartment of Orthopaedics, General Hospital of Jinan Military Commanding Region, Jinan, China.
Li-Li YuDepartment of Statistics, General Hospital of Jinan Military Commanding Region, Jinan, China.
Xiu-Chun YuDepartment of Orthopaedics, General Hospital of Jinan Military Commanding Region, Jinan, China.
General Hospital of Jinan Military Command · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo investigate the clinical feasibility and validity of interspinous fastener (ISF) for lumbar degenerative diseases.

methodsFrom October 2013 to March 2014, a total of 46 patients suffering from lumbar degenerative diseases underwent posterior lumbar interbody fusion (PLIF) randomly augmented by ISF or pedicle screws. The clinical outcome was primarily measured by Oswestry Disability Index (ODI) score. The minimal clinical important difference (MCID) was defined as an eight-point decrease in ODI. The second clinical outcome measurement was Japanese Orthopedic Association (JOA) score. Interbody fusion rates were evaluated by lumbar plain radiograph and computed tomography (CT) scan. Complications were also compared between groups. Statistical analyses were performed by SPSS version 13.0. Sample size calculation was performed before the study. The type I error α was set at 0.05 and the type II error β at 0.1. Based on these assumptions and adding 10% for possible drop-outs, sample size calculations indicated that a total of 46 patients were required for the study. Parametric data was compared by independent t-test and categorical variables were compared using χ

resultsA total of 43 patients completed the follow-up, with 22 cases in the ISF group and 21 patients in the pedicle screws group, respectively. Less intraoperative blood loss and shorter operation time were observed in the ISF group. The mean ODI significantly declined in both groups, with the ISF group's decreasing from preoperative 43.3 ± 8.2 to 21.4 ± 3.5 at 24-month follow-up and the pedicle screws group's decreasing from preoperative 42.9 ± 7.9 to 22.5 ±3.8 at 24-month follow-up, respectively. The ODI changes between groups had no statistical difference (P > 0.05). Of the 43 patients, 33 patients achieved an MCID. The bone fusion rate was 77.3% according to X-rays and 68.2% according to CT scans in the ISF group, and 81.0% according to X-rays and 76.2% according to CT scans in the pedicle screws group at the final follow-up. The intra-observer and inter-observer reliability assessed by the kappa value were 0.93 and 0.89, respectively. One patient in the pedicle screws group demonstrated screw loosening at the 6-month follow-up but was asymptomatic. One patient with spondylolisthesis in the ISF group demonstrated cage subsidence during the follow-up but also without related symptoms.

conclusionThe less invasive ISF combined with PLIF provided comparable clinical outcome and a similar bone fusion rate to pedicle screws. The ISF could potentially serve as a new alternative for lumbar degenerative diseases.

Indexed as

Pedicle ScrewsAdultAgedBlood Loss, SurgicalFemaleHumansIntervertebral Disc DegenerationLumbar VertebraeMagnetic Resonance ImagingMaleMiddle AgedObserver VariationOperative TimeProstheses and ImplantsSpinal FusionTomography, X-Ray ComputedFusion rateInterspinous fastenerLumbar degenerative diseasesPedicle screws