Observational studyAcademic emergency medicine : official journal of the Society for Academic Emergency Medicine2017
Undetectable Concentrations of a Food and Drug Administration-approved High-sensitivity Cardiac Troponin T Assay to Rule Out Acute Myocardial Infarction at Emergency Department Arrival.
Observational study in Academic emergency medicine : official journal of the Society for Academic Emergency Medicine, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed, 2 syntheses or guidelines pooled it.
- 2022 ACC Expert Consensus Decision Pathway on the Evaluation and Disposition of Acute Chest Pain in the Emergency Department: A Report of the American College of Cardiology Solution Set Oversight Committee.Journal of the American College of Cardiology · 2022Guideline
- High-sensitivity troponin assays for early rule-out of acute myocardial infarction in people with acute chest pain: a systematic review and economic evaluation.Health technology assessment (Winchester, England) · 2021Pooled it
- Revisiting High-Sensitivity Cardiac Troponin Abnormal Baseline Cutoffs: Implications for AMI Diagnosis in the Emergency Department.Journal of clinical medicine · 2025Article
- Evaluation of sex-specific 0-h high-sensitivity cardiac troponin T thresholds for the risk stratification of non-ST-segment elevation myocardial infarction.Clinical chemistry and laboratory medicine · 2025Article
- Article
- Machine learning for ECG diagnosis and risk stratification of occlusion myocardial infarction.Nature medicine · 2023Observational
- Machine Learning for the ECG Diagnosis and Risk Stratification of Occlusion Myocardial Infarction at First Medical Contact.Research square · 2023Article
- Article
- Contemporary Biomarker Strategies for Patients with Chest Pain.Reviews in cardiovascular medicine · 2022Review
- Association of a Novel Protocol for Rapid Exclusion of Myocardial Infarction With Resource Use in a US Safety Net Hospital.JAMA network open · 2020Article
- Article
- High-sensitivity troponin T and long-term adverse cardiac events among patients presenting with suspected acute coronary syndrome in Singapore.Singapore medical journal · 2019Observational
- Rapid rule-out of suspected acute coronary syndrome in the Emergency Department by high-sensitivity cardiac troponin T levels at presentation.Internal and emergency medicine · 2019Article
- Acute coronary syndromes diagnosis, version 2.0: Tomorrow's approach to diagnosing acute coronary syndromes?Turkish journal of emergency medicine · 2018Review
- Undetectable Concentrations of a Food and Drug Administration-approved High-sensitivity Cardiac Troponin T Assay to Rule Out Acute Myocardial Infarction at Emergency Department Arrival.Academic emergency medicine : official journal of the Society for Academic Emergency Medicine · 2017Observational
Corrections and comments
- Commented on by
Authors and funding
14 authors.
Funding
Abstract
backgroundThe objective of this study was to quantify the sensitivity of very low concentrations of high-sensitivity cardiac troponin T (hsTnT) at ED arrival for acute myocardial infarction (AMI) in a large cohort of chest pain patients evaluated in real-world clinical practice.
methodsThis retrospective study included consecutive ED patients with suspected cardiac chest pain evaluated in four urban EDs, excluding those with ST-elevation AMI, cardiac arrest or abnormal kidney function. The primary outcomes were AMI at 7, 30, and 90 days. Secondary outcomes included major adverse cardiac events (MACE; all-cause mortality, AMI, and revascularization) and the individual MACE components. Test characteristics were calculated for hsTnT values from 3 to 200 ng/L .
resultsA total of 7,130 patients met inclusion criteria. AMI incidences at 7, 30, and 90 days were 5.8, 6.0, and 6.2%. When the hsTnT assay was performed at ED arrival, the limit of blank of the assay (3 ng/L) ruled out 7-day AMI in 15.5% of patients with 100% sensitivity and negative predictive value (NPV). The limit of detection of the assay (5 ng/L) ruled out AMI in 33.6% of patients with 99.8% sensitivity and 99.95% NPV for 7-day AMI. The limit of quantification (the Food and Drug Administration [FDA]-approved cutoff for lower the reportable limit) of 6 ng/L ruled out AMI in 42.2% of patients with 99.8% sensitivity and 99.95% NPV. The sensitivities of the cutoffs of <3, <5, and <6 ng/L for 7-day MACE were 99.6, 97.4, and 96.6%, respectively. The NPVs of the cutoffs of <3, <5, and <6 ng/L for 7-day MACE were 99.8, 99.5, and 99.4%, respectively. A secondary analysis was performed in a subgroup of 3,549 higher-risk patients who underwent serial troponin testing. In this subgroup, a cutoff of 3 ng/L ruled out 7-day AMI in 9.6% of patients with 100% sensitivity and NPV, a cutoff of 5 ng/L ruled out 7-day AMI in 23.3% of patients with 99.7% sensitivity and 99.9% NPV, and a cutoff of 6 ng/L ruled out 7-day AMI in 29.8% of patients with 99.7 and 99.9% NPV. In the higher-risk subgroup, the sensitivities of cutoffs of <3, <5, and <6 ng/L for 7-day MACE were 99.8, 97.4, and 96.6%, respectively. In this higher-risk subgroup, the NPV of cutoffs of <3, <5, and <6 ng/L for 7-day MACE were 99.7, 98.5, and 98.4%, respectively.
conclusionsWhen used in real-world clinical practice conditions, hsTnT concentrations < 6 ng/L (below the lower reportable limit for an FDA-approved assay) at the time of ED arrival can rule out AMI with very high sensitivity and NPV. The sensitivity for MACE is unacceptably low, and thus a single-troponin rule-out strategy should only be used in the context of a structured risk evaluation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.