Evidence map›Paper›PMID 28543134›Full record

ArticleClinical cardiology2017

"Real life" longevity of implantable cardioverter-defibrillator devices.

Antonis S Manolis, Themistoklis Maounis, Spyridon Koulouris, Vassilios Vassilikos

Abstract readComparative Study
In one paragraph

Article in Clinical cardiology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Worldwide data analysis of BIOTRONIK ICD and CRT-D battery longevity.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2026
    Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Observational
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Antonis S ManolisThird Department of Cardiology, Athens University School of Medicine, Greece.ORCID http://orcid.org/0000-0002-0336-4745
Themistoklis MaounisDepartment of Cardiology, Onassis Cardiac Surgery Centre, Athens, Greece.
Spyridon KoulourisDepartment of Cardiology, Evangelismos Hospital, Athens, Greece.
Vassilios VassilikosThird Department of Cardiology, Hippokratio Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundManufacturers of implantable cardioverter-defibrillators (ICDs) promise a 5- to 9-year projected longevity; however, real-life data indicate otherwise. The aim of the present study was to assess ICD longevity among 685 consecutive patients over the last 20 years. HYPOTHESIS: Real-life longevity of ICDs may differ from that stated by the manufacturers.

methodsThe study included 601 men and 84 women (mean age, 63.1 ± 13.3 years). The underlying disease was coronary (n = 396) or valvular (n = 15) disease, cardiomyopathy (n = 220), or electrical disease (n = 54). The mean ejection fraction was 35%. Devices were implanted for secondary (n = 562) or primary (n = 123) prevention. Single- (n = 292) or dual-chamber (n = 269) or cardiac resynchronization therapy (CRT) devices (n = 124) were implanted in the abdomen (n = 17) or chest (n = 668).

resultsOver 20 years, ICD pulse generator replacements were performed in 238 patients (209 men; age 63.7 ± 13.9 years; ejection fraction, 37.7% ± 14.0%) who had an ICD for secondary (n = 210) or primary (n = 28) prevention. The mean ICD longevity was 58.3 ± 18.7 months. In 20 (8.4%) patients, devices exhibited premature battery depletion within 36 months. Most (94%) patients had none, minor, or modest use of ICD therapy. Longevity was longest for single-chamber devices and shortest for CRT devices. Latest-generation devices replaced over the second decade lasted longer compared with devices replaced during the first decade. When analyzed by manufacturer, Medtronic devices appeared to have longer longevity by 13 to 18 months.

conclusionsICDs continue to have limited longevity of 4.9 ± 1.6 years, and 8% demonstrate premature battery depletion by 3 years. CRT devices have the shortest longevity (mean, 3.8 years) by 13 to 17 months, compared with other ICD devices. These findings have important implications, particularly in view of the high expense involved with this type of electrical therapy.

Indexed as

Cardiac Resynchronization TherapyCardiac Resynchronization Therapy DevicesProsthesis FailureAdolescentAdultAgedAged, 80 and overCardiovascular DiseasesChildDeath, Sudden, CardiacDefibrillators, ImplantableElectric CountershockFemaleHumansKaplan-Meier EstimateMaleDefibrillator Battery DepletionImplantable Cardioverter-DefibrillatorPulse Generator ReplacementSudden Cardiac DeathVentricular FibrillationVentricular Tachycardia

Identifiers

PMID28543134
PMCPMC6490531

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.