Evidence map›Paper›PMID 28538369›Full record

Observational studyMedicine2017

Significant reduction of fluoroscopy repetition with lumbar localization system in minimally invasive spine surgery: A prospective study.

Guoxin Fan, Hailong Zhang, Xin Gu, Chuanfeng Wang, Xiaofei Guan, Yunshan Fan, Shisheng He

Open access · goldAbstract readObservational Study
In one paragraph

Observational study in Medicine, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.2field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 11 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Guoxin FanOrthopedic Department, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai, China.
Hailong Zhang
Xin Gu
Chuanfeng Wang
Xiaofei Guan
Yunshan Fan
Shisheng He
Tongji University · CNShanghai Tenth People's Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The conventional location methods for minimally invasive spinal surgery (MISS) were mainly based on repeated fluoroscopy in a trial-and-error manner preoperatively and intraoperatively. Localization system mainly consisted of preoperative applied radiopaque frame and intraoperative guiding device, which has the potential to minimize fluoroscopy repetition in MISS. The study aimed to evaluate the efficacy of a novel lumbar localization system in reducing radiation exposure to patients.Included patients underwent minimally invasive transforaminal lumbar interbody fusion (MISTLIF) or percutaneous transforaminal endoscopic discectomy (PTED). Patients treated with novel localization system were regarded as Group A, and patients treated without novel localization system were regarded as Group B.For PTED, The estimated effective dose was 0.41 ± 0.13 mSv in Group A and 0.57 ± 0.14 mSv in Group B (P < .001); the fluoroscopy exposure time of PTED was 22.18 ± 7.30 seconds in Group A and 30.53 ± 7.56 seconds in Group B (P < .001); The estimated cancer risk of radiation exposure was 22.68 ± 7.38 (10) in Group A and 31.20 ± 7.96 (10) in Group B (P < .001). For MISTLIF, the estimated effective dose was 0.45 ± 0.09 mSv in Group A and 0.58 ± 0.09 mSv in Group B (P < .001); The fluoroscopy exposure time was 25.41 ± 5.52 seconds in Group A and 32.82 ± 5.03 seconds in Group B (P < .001); The estimated cancer risk was 24.90 ± 5.15 (10) in Group A and 31.96 ± 5.04 (10) in Group B (P < .001). There were also significant differences in localization time and operation time between the 2 groups either for MISTLIF or PTED.The lumbar localization system could be a potential protection strategy for minimizing radiation hazards.

Indexed as

Diskectomy, PercutaneousFluoroscopyMinimally Invasive Surgical ProceduresSpinal FusionFemaleHumansLumbar VertebraeMaleMiddle AgedProspective StudiesRadiation DosageRadiation ExposureRiskTime Factors

Identifiers

PMID28538369
PMCPMC5457849
OpenAlexW2620352310

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.