ArticleExperimental eye research2017
Whole-globe biomechanics using high-field MRI.
Article in Experimental eye research, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
26 citing papers in PubMed, 37 citations in OpenAlex.
- MReye-Seg: development and validation of an automated MRI pipeline for standardised ocular and orbital morphometrics.Eye (London, England) · 2025Article
- Multiscale analysis of equatorial sclera anisotropy: Revealing discrepancies in fiber orientation and mechanical properties.Science advances · 2025Article
- Ultrafast line-field holographic elastography with single excitation for corneal biomechanical characterization.Biomedical optics express · 2025Article
- Acute alcohol consumption modulates corneal biomechanical properties as revealed by optical coherence elastography.Journal of biomechanics · 2024Article
- Study of the Influence of Boundary Conditions on Corneal Deformation Based on the Finite Element Method of a Corneal Biomechanics Model.Biomimetics (Basel, Switzerland) · 2024Article
- 2D or not 2D? Mapping the in-depth inclination of the collagen fibers of the corneoscleral shell.Experimental eye research · 2023Article
- Multifocal acoustic radiation force-based reverberant optical coherence elastography for evaluation of ocular globe biomechanical properties.Journal of biomedical optics · 2023Article
- Who bears the load? IOP-induced collagen fiber recruitment over the corneoscleral shell.Experimental eye research · 2023Article
- Regional differences of the sclera in the ocular hypertensive rat model induced by circumlimbal suture.Eye and vision (London, England) · 2023Article
- Review
- Comparing Acute IOP-Induced Lamina Cribrosa Deformations Premortem and Postmortem.Translational vision science & technology · 2022Article
- 3D Reconstruction of a Unitary Posterior Eye by Converging Optically Corrected Optical Coherence and Magnetic Resonance Tomography Images via 3D CAD.Translational vision science & technology · 2022Article
- A Workflow for Three-Dimensional Reconstruction and Quantification of the Monkey Optic Nerve Head Vascular Network.Journal of biomechanical engineering · 2022Article
- Micron-scale hysteresis measurement using dynamic optical coherence elastography.Biomedical optics express · 2022Article
- Diffusion Tensor Imaging of Visual Pathway Abnormalities in Five Glaucoma Animal Models.Investigative ophthalmology & visual science · 2021Article
- In vivo MRI evaluation of early postnatal development in normal and impaired rat eyes.Scientific reports · 2021Article
- Biomechanical properties of retina and choroid: a comprehensive review of techniques and translational relevance.Eye (London, England) · 2021Review
- Lamina Cribrosa Capillaries Straighten as Intraocular Pressure Increases.Investigative ophthalmology & visual science · 2020Article
- Role of radially aligned scleral collagen fibers in optic nerve head biomechanics.Experimental eye research · 2020Article
- Scleral structure and biomechanics.Progress in retinal and eye research · 2020Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 3 countries.
Funding
Abstract
The eye is a complex structure composed of several interconnected tissues acting together, across the whole globe, to resist deformation due to intraocular pressure (IOP). However, most work in the ocular biomechanics field only examines the response to IOP over smaller regions of the eye. We used high-field MRI to measure IOP induced ocular displacements and deformations over the whole globe. Seven sheep eyes were obtained from a local abattoir and imaged within 48 h using MRI at multiple levels of IOP. IOP was controlled with a gravity perfusion system and a cannula inserted into the anterior chamber. T2-weighted imaging was performed to the eyes serially at 0 mmHg, 10 mmHg, 20 mmHg and 40 mmHg of IOP using a 9.4 T MRI scanner. Manual morphometry was conducted using 3D visualization software to quantify IOP-induced effects at the globe scale (e.g. axial length and equatorial diameters) or optic nerve head scale (e.g. canal diameter, peripapillary sclera bowing). Measurement sensitivity analysis was conducted to determine measurement precision. High-field MRI revealed an outward bowing of the posterior sclera and anterior bulging of the cornea due to IOP elevation. Increments in IOP from 10 to 40 mmHg caused measurable increases in axial length in 6 of 7 eyes of 7.9 ± 5.7% (mean ± SD). Changes in equatorial diameter were minimal, 0.4 ± 1.2% between 10 and 40 mmHg, and in all cases less than the measurement sensitivity. The effects were nonlinear, with larger deformations at normal IOPs (10-20 mmHg) than at elevated IOPs (20-40 mmHg). IOP also caused measurable increases in the nasal-temporal scleral canal diameter of 13.4 ± 9.7% between 0 and 20 mmHg, but not in the superior-inferior diameter. This study demonstrates that high-field MRI can be used to visualize and measure simultaneously the effects of IOP over the whole globe, including the effects on axial length and equatorial diameter, posterior sclera displacement and bowing, and even changes in scleral canal diameter. The fact that the equatorial diameter did not change with IOP, in agreement with previous studies, indicates that a fixed boundary condition is a reasonable assumption for half globe inflation tests and computational models. Our results demonstrate the potential of high-field MRI to contribute to understanding ocular biomechanics, and specifically of the effects of IOP in large animal models.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.