Evidence map›Paper›PMID 28527390›Full record

ArticleWater research2017

On-filter direct amplification of Legionella pneumophila for rapid assessment of its abundance and viability.

Farag A Samhan, Tiffany M Stedtfeld, Hassan Waseem, Maggie R Williams, Robert D Stedtfeld, Syed A Hashsham

Abstract read
In one paragraph

Article in Water research, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. A Rapid and Sensitive CRISPR-Cas12a for the Detection ofPolish journal of microbiology · 2025
    Article
  3. Enhanced Detection of ViableMicroorganisms · 2024
    Article
  4. Article
  5. Article
  6. Rapid Detection and Differentiation ofFrontiers in chemistry · 2021
    Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Farag A SamhanDepartment of Civil and Environmental Engineering, Michigan State University, East Lansing, MI, USA.
Tiffany M StedtfeldDepartment of Civil and Environmental Engineering, Michigan State University, East Lansing, MI, USA.
Hassan WaseemDepartment of Civil and Environmental Engineering, Michigan State University, East Lansing, MI, USA.
Maggie R WilliamsDepartment of Civil and Environmental Engineering, Michigan State University, East Lansing, MI, USA.
Robert D StedtfeldDepartment of Civil and Environmental Engineering, Michigan State University, East Lansing, MI, USA.
Syed A HashshamDepartment of Civil and Environmental Engineering, Michigan State University, East Lansing, MI, USA; Center for Microbial Ecology, Michigan State University, East Lansing, MI, USA. Electronic address: hashsham@egr.msu.edu.

Funding

VOLATILE ORGANIC CONTAMINANTS--QUANTIFYING THEIR MOVEMENT IN THE UNSATURATED ZONEP42ES004911 · NIEHS · MICHIGAN STATE UNIVERSITY · PI Jamie J Bernard · 1989 to 2026
$64.9M
NIEHS NIH HHS P42 ES004911
6 · The paper itself

Abstract

Guidelines and regulations to control Legionella pneumophila in cooling water systems of large buildings are evolving due to the increasing number of outbreaks. Rapid, on-site, simple, and sensitive quantification methods that are also able to assess viability may be extremely useful in monitoring and control. Culture-based methods for measuring L. pneumophila may take 4-10 days and qPCR-based methods are also slow, requiring at least a day from sample to result, albeit mainly due to the need for sample transport to a centralized laboratory. This study reports a rapid isothermal amplification method for L. pneumophila concentration and detection with live/dead differentiation under field conditions. Using an on-filter direct amplification (i.e., amplification of cells without DNA extraction and purification) approach with propidium monoazide (PMA), and a real time isothermal amplification platform (Gene-Z), L. pneumophila could be detected in 1-2 h at ∼1 cfu/100 ml of tap water. Signature sequences from 16S rRNA and cadA genes were used as genetic markers for L. pneumophila and loop-mediated isothermal amplification (LAMP) primers were designed using Primer Explorer V4. Result were also compared with direct amplification of cells spiked into distilled, tap, and cooling water samples as well as extracted DNA by qPCR. This method may be useful to managers of cooling water systems in large buildings for rapid detection of L. pneumophila. The overall approach of on-site sample concentration, on-filter amplification, and live/dead differentiation may be extended to other organisms where analytical sensitivity and speed are equally important.

Indexed as

Nucleic Acid Amplification TechniquesReal-Time Polymerase Chain ReactionWater MicrobiologyDNA PrimersLegionellaLegionella pneumophilaRNA, Ribosomal, 16SSensitivity and SpecificityDNA PrimersRNA, Ribosomal, 16SDirect on-filter amplificationGene-ZLegionella pneumophilaLoop mediated isothermal amplificationPropidium monoazideRapid detectionSample processingViable cellsWater

Identifiers

PMID28527390
PMCPMC5525548

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.