Evidence map›Paper›PMID 28516215›Full record

SynthesisJournal of biological inorganic chemistry : JBIC : a publication of the Society of Biological Inorganic Chemistry2017

Are clinical findings of systemic titanium dispersion following implantation explained by available in vitro evidence? An evidence-based analysis.

Justin Paul Curtin, Minji Wang

Open access · greenAbstract readSystematic Review
PubMed Publisher
In one paragraph

Synthesis in Journal of biological inorganic chemistry : JBIC : a publication of the Society of Biological Inorganic Chemistry, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
0.7field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 11 citations in OpenAlex.

  1. In vivo assessment of TiOAnalytical and bioanalytical chemistry · 2024
    Article
  2. Article
  3. Electrical Potentiometry with Intraoral Applications.Materials (Basel, Switzerland) · 2022
    Article
  4. Review
  5. Article
  6. Review
  7. Article
  8. The role of citrate, lactate and transferrin in determining titanium release from surgical devices into human serum.Journal of biological inorganic chemistry : JBIC : a publication of the Society of Biological Inorganic Chemistry · 2018
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 2 countries.

Justin Paul CurtinOral and MaxilloFacial Surgery, Queen Mary Hospital, University of Hong Kong, Hong Kong, Hong Kong. jpcurtin@hku.hk.
Minji WangFaculty of Dentistry, University of Hong Kong, Hong Kong, Hong Kong.
University of Hong Kong · HK

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Although the presence of titanium wear particles released into tissues is known to induce local inflammation following the therapeutic implantation of titanium devices into humans, the role that titanium ions play in adverse tissue responses has received little attention. Support that ongoing titanium ion release occurs is evidenced by the presence of ionic titanium bound to transferrin in blood, and ongoing excretion in the urine of patients with titanium devices. However, as reports documenting the presence of titanium within tissues do not distinguish between particulate and ionic forms due to technical challenges, the degree to which ionic titanium is released into tissues is unknown. To determine the potential for titanium ion release into tissues, this study evaluates available in vitro evidence relating to the release of ionic titanium under physiological conditions. This is a systematic literature review of studies reporting titanium ion release into solutions from titanium devices under conditions replicating the interstitial pH and constituents. Inclusion and exclusion criteria were defined. Of 452 articles identified, titanium ions were reported in nine media relevant to human biology in seventeen studies. Only one study, using human serum replicated both physiological pH and the concentration of constituents while reporting the presence of titanium ions. While there is insufficient information to explain the factors that contribute to the presence of titanium ions in serum of humans implanted with titanium devices, currently available information suggests that areas of future inquiry include the role of transferrin and organic acids.

Indexed as

AnimalsEvidence-Based MedicineHumansProstheses and ImplantsTitaniumTitaniumCorrosionHumanReleaseSerumTitanium

Identifiers

PMID28516215
OpenAlexW2616410526

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.