Evidence map›Paper›PMID 28516045›Full record

ArticleQuantitative imaging in medicine and surgery2017

Exploration of highly accelerated magnetic resonance elastography using high-density array coils.

John C Bosshard, Naresh Yallapragada, Mary P McDougall, Steven M Wright

Open access · hybridAbstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 94% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

John C BosshardDepartment of Electrical and Computer Engineering, Texas A&M University, College Station, TX, USA.
Naresh YallapragadaDepartment of Electrical and Computer Engineering, Texas A&M University, College Station, TX, USA.
Mary P McDougallDepartment of Biomedical Engineering, Texas A&M University, College Station, TX, USA.
Steven M WrightDepartment of Electrical and Computer Engineering, Texas A&M University, College Station, TX, USA.
Texas A&M University · USTexas A&M Health Science Center · US

Funding

Transmit/Receive Single Echo Acquisition MRIR21EB005695 · NIBIB · TEXAS ENGINEERING EXPERIMENT STATION · PI WRIGHT, STEVEN M · 2006 to 2007
$399k
Wide Field MR Microscopy using Integrated Gradient and RF Array CoilsR21EB007649 · NIBIB · TEXAS ENGINEERING EXPERIMENT STATION · PI WRIGHT, STEVEN M · 2007 to 2008
$381k
NIBIB NIH HHS R21 EB005695NIBIB NIH HHS R21 EB007649
6 · The paper itself

Abstract

backgroundMagnetic resonance elastography (MRE) measures tissue mechanical properties by applying a shear wave and capturing its propagation using magnetic resonance imaging (MRI). By using high density array coils, MRE images are acquired using single echo acquisition (SEA) and at high resolutions with significantly reduced scan times.

methodsSixty-four channel uniplanar and 32×32 channel biplanar receive arrays are used to acquire MRE wave image sets from agar samples containing regions of varying stiffness. A mechanical actuator triggered by a stepped delay time introduces vibrations into the sample while a motion sensitizing gradient encodes micrometer displacements into the phase. SEA imaging is used to acquire each temporal offset in a single echo, while multiple echoes from the same array are employed for highly accelerated imaging at high resolutions. Additionally, stiffness variations as a function of temperature are studied by using a localized heat source above the sample. A custom insertable gradient coil is employed for phase compensation of SEA imaging with the biplanar array to allow imaging of multiple slices.

resultsSEA MRE images show a mechanical shear wave propagating into and across agar samples. A set of 720 images was obtained in 720 echoes, plus a single reference scan for both harmonic and transient MRE. A set of 2,950 wave image frames was acquired from pairs of SEA images captured during heating, showing the change in mechanical wavelength with the change in agar properties. A set of 240 frames was acquired from two slices simultaneously using the biplanar array, with phase images processed into displacement maps. Combining the narrow sensitivity patterns and SNR advantage of the SEA array coil geometry allowed acquisition of a data set with a resolution of 156 µm × 125 µm × 1,000 µm in only 64 echoes, demonstrating high resolution and high acceleration factors.

conclusionsMRE using high-density arrays offers the unique ability to acquire a single frame of a propagating mechanical vibration with each echo, which may be helpful in non-repeatable or destructive testing. Highly accelerated, high resolution MRE may be enabled by the use of large arrays of coils such as used for SEA, but at lower acceleration rates supporting the higher resolution than provided by SEA imaging.

Indexed as

gradient coilsmagnetic resonance elastography (MRE)Magnetic resonance imaging (MRI)parallel imagingRF coil arrayssingle echo acquisition (SEA)

Identifiers

PMID28516045
PMCPMC5418148
OpenAlexW2609470232

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.