Evidence map›Paper›PMID 28508491›Full record

ArticleJournal of applied clinical medical physics2017

Implementation of absolute quantification in small-animal SPECT imaging: Phantom and animal studies.

Shabnam Khorasani Gerdekoohi, Naser Vosoughi, Kaveh Tanha, Majid Assadi, Pardis Ghafarian, Arman Rahmim, Mohammad Reza Ay

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Pre-clinical SPECT and SPECT-CT in Oncology.Recent results in cancer research. Fortschritte der Krebsforschung. Progres dans les recherches sur le cancer · 2026
    Review
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Shabnam Khorasani GerdekoohiDepartment of Energy Engineering, Sharif University of Technology, Tehran, Iran.
Naser VosoughiDepartment of Energy Engineering, Sharif University of Technology, Tehran, Iran.
Kaveh TanhaThe Persian Gulf Nuclear Medicine Research Center, Bushehr University of Medical Sciences, Bushehr, Iran.
Majid AssadiThe Persian Gulf Nuclear Medicine Research Center, Bushehr University of Medical Sciences, Bushehr, Iran.
Pardis GhafarianChronic Respiratory Diseases Research Center, National Research Institute of Tuberculosis and Lung Diseases (NRITLD), Shahid Beheshti University of Medical Sciences, Tehran, Iran.
Arman RahmimDepartment of Radiology, Johns Hopkins University, Baltimore, Maryland, USA.
Mohammad Reza AyResearch Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposePresence of photon attenuation severely challenges quantitative accuracy in single-photon emission computed tomography (SPECT) imaging. Subsequently, various attenuation correction methods have been developed to compensate for this degradation. The present study aims to implement an attenuation correction method and then to evaluate quantification accuracy of attenuation correction in small-animal SPECT imaging.

methodsImages were reconstructed using an iterative reconstruction method based on the maximum-likelihood expectation maximization (MLEM) algorithm including resolution recovery. This was implemented in our designed dedicated small-animal SPECT (HiReSPECT) system. For accurate quantification, the voxel values were converted to activity concentration via a calculated calibration factor. An attenuation correction algorithm was developed based on the first-order Chang's method. Both phantom study and experimental measurements with four rats were used in order to validate the proposed method.

resultsThe phantom experiments showed that the error of -15.5% in the estimation of activity concentration in a uniform region was reduced to +5.1% when attenuation correction was applied. For in vivo studies, the average quantitative error of -22.8 ± 6.3% (ranging from -31.2% to -14.8%) in the uncorrected images was reduced to +3.5 ± 6.7% (ranging from -6.7 to +9.8%) after applying attenuation correction.

conclusionThe results indicate that the proposed attenuation correction algorithm based on the first-order Chang's method, as implemented in our dedicated small-animal SPECT system, significantly improves accuracy of the quantitative analysis as well as the absolute quantification.

Indexed as

AlgorithmsImage Processing, Computer-AssistedPhantoms, ImagingAnimalsPhotonsRadiation DosageRatsTomography, Emission-Computed, Single-Photonattenuation correctionquantificationsmall-animal imagingSPECT imaging

Identifiers

PMID28508491
PMCPMC5874931

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.