ArticleBiomedical engineering online2017
Computational fluid dynamics study of intra-arterial chemotherapy for oral cancer.
Article in Biomedical engineering online, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Diameters of lingual, facial, and maxillary arteries measured according to an objective protocol on 3D computed tomography angiography images.International journal of computer assisted radiology and surgery · 2024Article
- Efficacy and Safety of Intro-Arterial Chemotherapy Combined with Radiotherapy on Head and Neck Cancer: A Systematic Review and Meta-Analysis.Journal of Cancer · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundIntra-arterial chemotherapy (IAC) for oral cancer can deliver a higher concentration of anticancer agent into a tumor-feeding artery than intravenous systemic chemotherapy. However, distribution of anticancer agent into several branches of the external carotid artery (ECA) in IAC has not demonstrated sufficient treatment efficacy. To improve the effectiveness of IAC, the flow distribution of anticancer agent into the branches of the ECA in several IAC methods was investigated using computational fluid dynamics (CFD).
methodsPatient-specific three-dimensional vessel models were created from CT images of 2 patients with tongue cancer. Catheter models were combined with the vessel models. Thirty-two models were generated with varying vertical and horizontal positions of the catheter tip. With the use of a zero-dimensional resistance model of the peripheral vessel network, conventional IAC and superselective IAC were simulated in 30 and 2 models, respectively. The flow distribution of anticancer agent into the branches of the ECA was investigated in 32 models. Additionally, the blood streamline was traced from the inlet of the common carotid artery toward each outlet to examine the flow of anticancer agent in all models, and the wall shear stress of the vessel was calculated for some models.
resultsThe CFD simulations could be conducted within a reasonable computational time. In several models, the anticancer agent flowed into the target artery only when the catheter tip was located below the bifurcation of the ECA and each target artery. Furthermore, the anticancer agent tended to flow into the target artery when the catheter tip was shifted toward the target artery. In all ECA branches that had flow of anticancer agent, the blood streamlines to the target arteries contacted the catheter tip. Anticancer agent flowed into only the target artery in patients' models for superselective IAC. However, high wall shear stress was observed at the target artery in one patient's model.
conclusionsThis CFD study showed that location of the catheter tip was important in controlling the anticancer agent in conventional IAC. The distribution rate of anticancer agent into the tumor-feeding artery tended to increase when the catheter tip was placed below and toward the target artery. Although superselective IAC can reliably supply anticancer agent to the target artery, high wall shear stress at the target artery can occur, depending on vessel geometry of the patient, which may cause serious complications during the treatment.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.