ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2018
Anterior referencing of tibial slope in total knee arthroplasty considerably influences knee kinematics: a musculoskeletal simulation study.
Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed, 32 citations in OpenAlex.
- Systemic Cobalt Toxicity Secondary to Tibial Component Malpositioning in Bilateral Primary Total Knee Arthroplasties.Arthroplasty today · 2026Article
- Effect of tibial rotational alignment and posterior slope on joint biomechanics in posterior-stabilized total knee arthroplasty: a finite element study.European journal of medical research · 2025Article
- Measuring Posterior Tibial Slope: A Comparison Using a 10-cm Anatomic Axis Versus 15-cm Anatomic Axis.Orthopaedic journal of sports medicine · 2025Article
- Risk Factors for Postoperative Knee Stiffness in Patients with Anteromedial Knee Osteoarthritis Undergoing Unicompartmental Knee Arthroplasty with Cemented Prostheses: A Short-Term, Retrospective, Case-Control Study.Medical science monitor : international medical journal of experimental and clinical research · 2023Article
- Subject-specific tribo-contact conditions in total knee replacements: a simulation framework across scales.Biomechanics and modeling in mechanobiology · 2023Article
- Pre-Planning the Surgical Target for Optimal Implant Positioning in Robotic-Assisted Total Knee Arthroplasty.Bioengineering (Basel, Switzerland) · 2023Article
- Risk factors of de novo hyperextension developed after posterior cruciate ligament substituting total knee arthroplasty: a matched case-control study.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2023Article
- Biomechanical Effect of Coronal Alignment and Ligament Laxity in Total Knee Arthroplasty: A Simulation Study.Frontiers in bioengineering and biotechnology · 2022Article
- There are isoheight points that measure constant femoral condyle heights along the knee flexion path.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2021Article
- [Importance of the tibial slope in knee arthroplasty].Der Orthopade · 2020Review
- Effect of sagittal femoral component alignment on biomechanics after mobile-bearing total knee arthroplasty.Journal of orthopaedic surgery and research · 2019Article
- Article
- Effect of surgical parameters on the biomechanical behaviour of bicondylar total knee endoprostheses - A robot-assisted test method based on a musculoskeletal model.Scientific reports · 2019Article
- Predictors for secondary patellar resurfacing after primary total knee arthroplasty using a "patella-friendly" total knee arthroplasty system.International orthopaedics · 2019Article
- Posterior tibial slope impacts intraoperatively measured mid-flexion anteroposterior kinematics during cruciate-retaining total knee arthroplasty.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2018Article
- The increase in posterior tibial slope provides a positive biomechanical effect in posterior-stabilized total knee arthroplasty.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 5 institutions in 1 country.
Funding
Abstract
purposeIn total knee arthroplasty (TKA), the posterior tibial slope is not always reconstructed correctly, and the knee ligaments may become too tight in flexion. To release a tight flexion gap, surgeons can increase the posterior tibial slope using two surgical resection techniques: the anterior tibial cortex (ACR) or the centre of tibial plateau (CPR) referencing. It is not known how this choice affects the knee laxity and function during activities of daily living. The aim of this study was to investigate the effect of tibial slope on knee laxity, kinematics and forces during a squatting activity using computer simulation techniques. We hypothesised that the effects depend on the referencing technique utilised.
methodsA validated musculoskeletal model of TKA was used. Knee laxity tests were simulated in flexion and extension. Then, a squat motion was simulated to calculate: movement of the tibiofemoral joint (TFJ) contact points and patello-femoral joint (PFJ) contact force. All analyses were repeated with more anterior (-3°), neutral (0°), and more posterior tibial slope (+3°, +6°, +9°), and with two referencing techniques (ACR, CPR).
resultsKnee laxities increased dramatically with more posterior slope with the ACR technique (up to 400%), both in flexion and in extension. The CPR technique, instead, had much smaller effects (up to 42% variations). During squatting, more slope with the ACR technique resulted in larger movements of the TFJ contact point. The PFJ contact force decreased considerably with more slope with the CPR technique (12% body weight reduction every 3° more posterior slope), thanks to the preservation of the patellar height and quadriceps-femur load sharing.
conclusionACR technique alters considerably the knee laxity, both in flexion and extensions, and surgeons should be cautious about its use. More slope with CPR technique induces more favourable TFJ kinematics and loading of the knee extensor apparatus and does not substantially alter knee laxity. Preferably, the tibial slope resection should be pre-planned thoroughly and performed using CPR technique as accurately as possible. Surgeons can directly translate the results of this study into the clinical practice.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials