Evidence map›Paper›PMID 28497418›Full record

ArticleJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology2019

Assessing time-of-flight signal-to-noise ratio gains within the myocardium and subsequent reductions in administered activity in cardiac PET studies.

Ian S Armstrong, Christine M Tonge, Parthiban Arumugam

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.3field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. EANM procedural guidelines for PET/CT quantitative myocardial perfusion imaging.European journal of nuclear medicine and molecular imaging · 2021
    Article
  4. Does time-of-flight improve image quality in the heart?Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2019
    Article
  5. Understanding the impact of advanced PET reconstruction in cardiac PET: The devil is in the details.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2018
    Article
  6. The effect of time-of-flight and point spread function modeling onJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2018
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Ian S ArmstrongNuclear Medicine, Central Manchester University Hospitals, Oxford Road, Manchester, M13 9WL, UK. Ian.Armstrong@cmft.nhs.uk.ORCID 0000-0003-2507-6012
Christine M TongeNuclear Medicine, Central Manchester University Hospitals, Oxford Road, Manchester, M13 9WL, UK.
Parthiban ArumugamNuclear Medicine, Central Manchester University Hospitals, Oxford Road, Manchester, M13 9WL, UK.
University of Manchester · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTime-of-flight (TOF) is known to increase signal-to-noise ratio (SNR) and facilitate reductions in administered activity. Established measures of SNR gain are derived from areas of uniform uptake, which is not applicable to the heterogeneous uptake in cardiac PET images using fluoro-deoxyglucose (FDG). This study aimed to develop a technique to quantify SNR gains within the myocardium due to TOF.

methodsReference TOF SNR gains were measured in 88 FDG oncology patients. Phantom data were used to translate reference SNR gains and validate a method of quantifying SNR gains within the myocardium from parametric images produced from multiple replicate images. This technique was applied to 13 FDG cardiac viability patients.

resultsReference TOF SNR gains of +23% ± 8.5% were measured in oncology patients. Measurements of SNR gain from the phantom data were in agreement and showed the parametric image technique to be sufficiently robust. SNR gains within the myocardium in the viability patients were +21% ± 2.8%.

conclusionA method to quantify SNR gains from TOF within the myocardium has been developed and evaluated. SNR gains within the myocardium are comparable to those observed by established methods. This allows guidance for protocol optimization for TOF systems in cardiac PET.

Indexed as

Positron-Emission TomographyPositron Emission Tomography Computed TomographyFluorodeoxyglucose F18HeartHumansLiverMyocardiumPhantoms, ImagingRubidium RadioisotopesSignal-To-Noise RatioFluorodeoxyglucose F18Rubidium-82Rubidium Radioisotopesbasic scienceimage qualityimage reconstructionMyocardial perfusion imaging: PETPET/CT imaging

Identifiers

PMID28497418
OpenAlexW2613802961

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked