Evidence map›Paper›PMID 28496414›Full record

ArticleFrontiers in physiology2017

The Systematic Bias of Ingestible Core Temperature Sensors Requires a Correction by Linear Regression.

Andrew P Hunt, Aaron J E Bach, David N Borg, Joseph T Costello, Ian B Stewart

Abstract read
In one paragraph

Article in Frontiers in physiology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Andrew P HuntFaculty of Health, School of Exercise and Nutrition Sciences, Institute of Health and Biomedical Innovation, Queensland University of TechnologyBrisbane, QLD, Australia.
Aaron J E BachFaculty of Health, School of Exercise and Nutrition Sciences, Institute of Health and Biomedical Innovation, Queensland University of TechnologyBrisbane, QLD, Australia.
David N BorgFaculty of Health, School of Exercise and Nutrition Sciences, Institute of Health and Biomedical Innovation, Queensland University of TechnologyBrisbane, QLD, Australia.
Joseph T CostelloExtreme Environments Laboratory, Department of Sport and Exercise Science, University of PortsmouthPortsmouth, UK.
Ian B StewartFaculty of Health, School of Exercise and Nutrition Sciences, Institute of Health and Biomedical Innovation, Queensland University of TechnologyBrisbane, QLD, Australia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

An accurate measure of core body temperature is critical for monitoring individuals, groups and teams undertaking physical activity in situations of high heat stress or prolonged cold exposure. This study examined the range in systematic bias of ingestible temperature sensors compared to a certified and traceable reference thermometer. A total of 119 ingestible temperature sensors were immersed in a circulated water bath at five water temperatures (TEMP A: 35.12 ± 0.60°C, TEMP B: 37.33 ± 0.56°C, TEMP C: 39.48 ± 0.73°C, TEMP D: 41.58 ± 0.97°C, and TEMP E: 43.47 ± 1.07°C) along with a certified traceable reference thermometer. Thirteen sensors (10.9%) demonstrated a systematic bias > ±0.1°C, of which 4 (3.3%) were > ± 0.5°C. Limits of agreement (95%) indicated that systematic bias would likely fall in the range of -0.14 to 0.26°C, highlighting that it is possible for temperatures measured between sensors to differ by more than 0.4°C. The proportion of sensors with systematic bias > ±0.1°C (10.9%) confirms that ingestible temperature sensors require correction to ensure their accuracy. An individualized linear correction achieved a mean systematic bias of 0.00°C, and limits of agreement (95%) to 0.00-0.00°C, with 100% of sensors achieving ±0.1°C accuracy. Alternatively, a generalized linear function (Corrected Temperature (°C) = 1.00375 × Sensor Temperature (°C) - 0.205549), produced as the average slope and intercept of a sub-set of 51 sensors and excluding sensors with accuracy outside ±0.5°C, reduced the systematic bias to < ±0.1°C in 98.4% of the remaining sensors (

Indexed as

coldgastrointestinal temperatureheatingestible sensormeasurement errorreliabilitythermoregulationvalidity

Identifiers

PMID28496414
PMCPMC5406512

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked