Evidence map›Paper›PMID 28493110›Full record

ArticleInternational journal of computer assisted radiology and surgery2017

BEM-based simulation of lung respiratory deformation for CT-guided biopsy.

Dong Chen, Weisheng Chen, Lipeng Huang, Xuegang Feng, Terry Peters, Lixu Gu

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. A statistical weighted sparse-based local lung motion modelling approach for model-driven lung biopsy.International journal of computer assisted radiology and surgery · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Dong ChenSchool of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
Weisheng ChenDepartment of Cardiothoracic Surgery, Affiliated East Hospital of Xiamen University, Fuzhou, China.
Lipeng HuangDepartment of Cardiothoracic Surgery, Affiliated East Hospital of Xiamen University, Fuzhou, China.
Xuegang FengDepartment of Cardiothoracic Surgery, Affiliated East Hospital of Xiamen University, Fuzhou, China.
Terry PetersRobarts Research Institute, Western University, London, Canada.
Lixu GuSchool of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China. gulixu@sjtu.edu.cn.

Funding

the National Natural Science Foundation of China 61190124the National Natural Science Foundation of China 81301283
6 · The paper itself

Abstract

purposeAccurate and real-time prediction of the lung and lung tumor deformation during respiration are important considerations when performing a peripheral biopsy procedure. However, most existing work focused on offline whole lung simulation using 4D image data, which is not applicable in real-time image-guided biopsy with limited image resources. In this paper, we propose a patient-specific biomechanical model based on the boundary element method (BEM) computed from CT images to estimate the respiration motion of local target lesion region, vessel tree and lung surface for the real-time biopsy guidance.

methodsThis approach applies pre-computation of various BEM parameters to facilitate the requirement for real-time lung motion simulation. The resulting boundary condition at end inspiratory phase is obtained using a nonparametric discrete registration with convex optimization, and the simulation of the internal tissue is achieved by applying a tetrahedron-based interpolation method depend on expert-determined feature points on the vessel tree model. A reference needle is tracked to update the simulated lung motion during biopsy guidance.

resultsWe evaluate the model by applying it for respiratory motion estimations of ten patients. The average symmetric surface distance (ASSD) and the mean target registration error (TRE) are employed to evaluate the proposed model. Results reveal that it is possible to predict the lung motion with ASSD of [Formula: see text] mm and a mean TRE of [Formula: see text] mm at largest over the entire respiratory cycle. In the CT-/electromagnetic-guided biopsy experiment, the whole process was assisted by our BEM model and final puncture errors in two studies were 3.1 and 2.0 mm, respectively.

conclusionThe experiment results reveal that both the accuracy of simulation and real-time performance meet the demands of clinical biopsy guidance.

Indexed as

Models, BiologicalComputer SimulationHumansImage-Guided BiopsyLungLung NeoplasmsMovementTomography, X-Ray ComputedBiomechanical modelBiopsyBoundary element methodLung motion prediction

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.