ArticleMedicine2017
Adverse local tissue reaction after 2 revision hip replacements for ceramic liner fracture: A case report.
Article in Medicine, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 23 citations in OpenAlex.
- Suitability of Mg-Nd and Mg-Zn Alloys to Obtain Biodegradable Structures for Bone Defects.Journal of functional biomaterials · 2025Article
- Ceramic fragmentation after total hip arthroplasty: two case reports and literature review.Frontiers in surgery · 2024Article
- Failure Analysis of Ultra-High Molecular Weight Polyethylene Tibial Insert in Total Knee Arthroplasty.Materials (Basel, Switzerland) · 2022Article
- Essential Oils as Antimicrobial Active Substances in Wound Dressings.Materials (Basel, Switzerland) · 2022Article
- Effect of the Antimicrobial Agents Peppermint Essential Oil and Silver Nanoparticles on Bone Cement Properties.Biomimetics (Basel, Switzerland) · 2022Article
- Bone Cements Used for Hip Prosthesis Fixation: The Influence of the Handling Procedures on Functional Properties Observed during In Vitro Study.Materials (Basel, Switzerland) · 2022Article
- An Atypical Adverse Local Tissue Reaction After Ceramic-on-Ceramic Primary Total Hip Arthroplasty.Arthroplasty today · 2022Article
- Causes of revision after total hip arthroplasty in an orthopedics and traumatology regional center.Medicine and pharmacy reports · 2022Article
- Surgical Treatment in a High-Risk Pulmonary Embolism: Case Report.Medicina (Kaunas, Lithuania) · 2021Article
- Failure Analysis of Retrieved Osteosynthesis Implants.Materials (Basel, Switzerland) · 2020Article
- Rare Breast Carcinoma with Paradoxical Plasma Cell Immunoprofile: A Case Report.Medicina (Kaunas, Lithuania) · 2020Article
- Fatal outcome of gastric perforation due to infection with Sarcina spp. A case report.IDCases · 2020Article
- Splenectomy in Lymphoproliferative Disorders: A Single Eastern European Center Experience.Medicina (Kaunas, Lithuania) · 2019Observational
- Naturally-Derived Biphasic Calcium Phosphates through Increased Phosphorus-Based Reagent Amounts for Biomedical Applications.Materials (Basel, Switzerland) · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionIn younger patients, ceramic-on-ceramic (CoC) bearing surfaces are usually recommended for total hip replacement (THR) because of their low wear rate and longer expected functional life. Although technical advancements have reduced the risk of ceramic bearings fracture, this complication remains a major concern. CASE DESCRIPTION: We present the case of a 56-year-old patient undergoing 3 revision hip arthroplasties of the right hip due to ceramic liner fractures. Initial THR (2008) was performed with a CoC bearing, followed by liner fracture due to trauma a year later. The acetabular component and liner were replaced, with a minor incongruence between the old head and new insert. The 2nd ceramic insert fractured 3.5 years later, following minor trauma. Upon revision, the bearing surface was changed to metal-on-polyethylene (MoP). The performed retrieval analysis demonstrated stripe and rim wear, and evidence of adhesive wear. The patient was referred to us a month later, with a fistula on the lateral side of the hip, discharging black, petroleum-like liquid. Radiology showed well-fixed implants, no dislocation and no apparent polyethylene wear. Microbiological assessment of the discharge showed no infection. Intraoperatively massive metallosis was noticed, with stable acetabular and femoral components. The metal femoral head was heavily abraded, with almost 1% volumetric wear. Hematoxylin and eosin stained frozen tissue samples showed muscular and adipose tissue necrosis, while polarized light microscopy highlighted metal, polyethylene, and ceramic particles.
conclusionThe present case is yet another report showing the adverse outcomes of using MoP bearings for revision after ceramic liner fracture in THR.