Evidence map›Paper›PMID 28488238›Full record

ArticleInternational journal of computer assisted radiology and surgery2017

Trans-oral miniature X-ray radiation delivery system with endoscopic optical feedback.

Axel Boese, Fredrick Johnson, Till Ebert, Ali Mahmoud-Pashazadeh, Christoph Arens, Michael Friebe

Open access · hybridAbstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.3field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Axel BoeseChair for Catheter Technologies, Otto-von-Guericke University, Universitätsplatz 2, 39106, Magdeburg, Germany. axel.boese@ovgu.de.ORCID http://orcid.org/0000-0002-5874-7145
Fredrick JohnsonChair for Catheter Technologies, Otto-von-Guericke University, Universitätsplatz 2, 39106, Magdeburg, Germany.
Till EbertChair for Catheter Technologies, Otto-von-Guericke University, Universitätsplatz 2, 39106, Magdeburg, Germany.
Ali Mahmoud-PashazadehChair for Catheter Technologies, Otto-von-Guericke University, Universitätsplatz 2, 39106, Magdeburg, Germany.
Christoph ArensClinic of ENT, Otto-von-Guericke University, Leipziger Str. 44, 39120, Magdeburg, Germany.
Michael FriebeChair for Catheter Technologies, Otto-von-Guericke University, Universitätsplatz 2, 39106, Magdeburg, Germany.
Otto-von-Guericke-Universität Magdeburg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeSurgery, chemo- and/or external radiation therapy are the standard therapy options for the treatment of laryngeal cancer. Trans-oral access for the surgery reduces traumata and hospitalization time. A new trend in treatment is organ-preserving surgery. To avoid regrowth of cancer, this type of surgery can be combined with radiation therapy. Since external radiation includes healthy tissue surrounding the cancerous zone, a local and direct intraoral radiation delivery would be beneficial.

methodsA general concept for a trans-oral radiation system was designed, based on clinical need identification with a medical user. A miniaturized X-ray tube was used as the radiation source for the intraoperative radiation delivery. To reduce dose distribution on healthy areas, the X-ray source was collimated by a newly designed adjustable shielding system as part of the housing. For direct optical visualization of the radiation zone, a miniature flexible endoscope was integrated into the system. The endoscopic light cone and the field of view were aligned with the zone of the collimated radiation. The intraoperative radiation system was mounted on a semi-automatic medical holder that was combined with a frontal actuator for rotational and translational movement using piezoelectric motors to provide precise placement.

resultsThe entire technical set-up was tested in a simulated environment. The shielding of the X-ray source was verified by performing conventional detector-based dose measurements. The delivered dose was estimated by an ionization chamber. The adjustment of the radiation zone was performed by a manual controlling mechanism integrated into the hand piece of the device. An endoscopic fibre was also added to offer visualization and illumination of the radiation zone. The combination of the radiation system with the semi-automatic holder and actuator offered precise and stable positioning of the device in range of micrometres and will allow for future combination with a radiation planning system.

conclusionsThe presented system was designed for radiation therapy of the oral cavity and the larynx. This first set-up tried to cover all clinical aspects that are necessary for a later use in surgery. The miniaturized X-ray tube offers the size and the power for intraoperative radiation therapy. The adjustable shielding system in combination with the holder and actuator provides a precise placement. The visualization of radiation zone allows a targeting and observation of the radiation zone.

Indexed as

Otorhinolaryngologic Surgical ProceduresEquipment DesignHumansLaryngeal NeoplasmsLaryngoscopyMiniaturizationOrgan Sparing TreatmentsRadiation DosageRadiotherapyRadiotherapy, AdjuvantX-RaysX-Ray TherapyENTMiniaturized X-ray tubeMinimal invasive therapyOrgan-preserving surgeryRadiation therapyTrans-oral surgeryTumour bed radiation

Identifiers

PMID28488238
PMCPMC5656715
OpenAlexW2613034576

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.