Evidence map›Paper›PMID 28487829›Full record

ArticleJournal of medical signals and sensors

Multi-parametric Improvements in the CCD Camera-based EPID for Portal Dosimetry.

Vahideh Nazari, Seied R Mahdavi, Ahmad Mostaar, Hassan Nedaei, Mohammad A Mosleh Shirazi, Alireza Nikoofar, Golbarg Esmailie

Open access · diamondAbstract read
In one paragraph

Article in Journal of medical signals and sensors. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact, top 96% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 1 country.

Vahideh NazariMedical Physics Department, Iran University of Medical Sciences, Tehran, Iran.
Seied R MahdaviMedical Physics Department, Iran University of Medical Sciences, Tehran, Iran.
Ahmad MostaarMedical Physics and Biomedical Engineering Department, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
Hassan NedaeiImam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran.
Mohammad A Mosleh ShiraziMedical Physics Department, Shiraz University of Medical Sciences, Shiraz, Iran.
Alireza NikoofarMedical Physics Department, Shiraz University of Medical Sciences, Shiraz, Iran.
Golbarg EsmailieRadiotherapy Department, Iran University of Medical Sciences, Tehran, Iran.
Iran University of Medical Sciences · IRShiraz University of Medical Sciences · IRShahid Beheshti University of Medical Sciences · IRTehran University of Medical Sciences · IR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Dosimetric verification of radiation treatment has recently been extended by the introduction of electronic portal imaging devices (EPIDs). Detailed dose response specifications of EPID should be addressed prior to any dosimetric application. The present study evaluates improvements of dosimetric properties of the low elbow camera-based EPID Theraview (Cablon Medical, Leusden, The Netherlands) equipped with a cooled charge coupled device (CCD) for portal dosimetry. The dose response, warm-up behavior, stability over long- and short-term scales (throughout a day) were studied. The field size dependency of the EPID response was also investigated and compared with ion chamber measurements under the same conditions. The EPID response without saturation for doses up to 2 Gy was linear for both beam qualities (6 and 15 MV). There was no evident warm-up characteristic. The detector sensitivity showed excellent stability in short term [standard deviation (SD) 0.38%]. In long-term stability (over a period of approximately 3 months), a negligible linear decline of 0.01% per day was observed. It was concluded that the cooled CCD camera-based EPID could be used for portal dosimetry, after accurate corrections for the field size dependency and sensitivity loss.

Indexed as

elbowElectronic portal imaging devicesportal dosimetryradiometry

Identifiers

PMID28487829
PMCPMC5394802
OpenAlexW2607732449

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.