Reliable sagittal plane kinematic gait assessments are feasible using low-cost webcam technology.

Robert J Saner, Edward P Washabaugh, Chandramouli Krishnan

Abstract readClinical Trial
In one paragraph

Trial report in Gait & posture, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Vision-based gait impairment analysis for aided diagnosis.Medical & biological engineering & computing · 2018
    Article
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Robert J SanerDepartment of Physical Medicine and Rehabilitation, University of Michigan Medical School, Ann Arbor, MI, USA; School of Kinesiology, University of Michigan, Ann Arbor, MI, USA.
Edward P WashabaughDepartment of Physical Medicine and Rehabilitation, University of Michigan Medical School, Ann Arbor, MI, USA; Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA.
Chandramouli KrishnanDepartment of Physical Medicine and Rehabilitation, University of Michigan Medical School, Ann Arbor, MI, USA; Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA; School of Kinesiology, University of Michigan, Ann Arbor, MI, USA. Electronic address: mouli@umich.edu.

Funding

NRI: Wearable eMbots to Induce Recovery of FunctionR01EB019834 · NIBIB · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI DURFEE, WILLIAM K, GILLESPIE, RICHARD BRENT · 2014 to 2016
$854k
NIBIB NIH HHS R01 EB019834
6 · The paper itself

Abstract

Three-dimensional (3-D) motion capture systems are commonly used for gait analysis because they provide reliable and accurate measurements. However, the downside of this approach is that it is expensive and requires technical expertise; thus making it less feasible in the clinic. To address this limitation, we recently developed and validated (using a high-precision walking robot) a low-cost, two-dimensional (2-D) real-time motion tracking approach using a simple webcam and LabVIEW Vision Assistant. The purpose of this study was to establish the repeatability and minimal detectable change values of hip and knee sagittal plane gait kinematics recorded using this system. Twenty-one healthy subjects underwent two kinematic assessments while walking on a treadmill at a range of gait velocities. Intraclass correlation coefficients (ICC) and minimal detectable change (MDC) values were calculated for commonly used hip and knee kinematic parameters to demonstrate the reliability of the system. Additionally, Bland-Altman plots were generated to examine the agreement between the measurements recorded on two different days. The system demonstrated good to excellent reliability (ICC>0.75) for all the gait parameters tested on this study. The MDC values were typically low (<5°) for most of the parameters. The Bland-Altman plots indicated that there was no systematic error or bias in kinematic measurements and showed good agreement between measurements obtained on two different days. These results indicate that kinematic gait assessments using webcam technology can be reliably used for clinical and research purposes.

Indexed as

AdultBiomechanical PhenomenaFeasibility StudiesFemaleGaitHealthy VolunteersHip JointHumansInternetKnee JointMaleMichiganReproducibility of ResultsVideo RecordingBiomechanicsCamera systemsGait trackingKinematic analysisReal-time

Identifiers

PMID28482201
PMCPMC5515224

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.