Evidence map›Paper›PMID 28477219›Full record

ArticleClinical rheumatology2017

Reliability of ultrasound grading traditional score and new global OMERACT-EULAR score system (GLOESS): results from an inter- and intra-reading exercise by rheumatologists.

Lucio Ventura-Ríos, Cristina Hernández-Díaz, Diana Ferrusquia-Toríz, Esteban Cruz-Arenas, Pedro Rodríguez-Henríquez, Ana Laura Alvarez Del Castillo, Alfredo Campaña-Parra, Efrén Canul, Gerardo Guerrero Yeo, Juan Jorge Mendoza-Ruiz and 4 more

Abstract read
PubMed Publisher
In one paragraph

Article in Clinical rheumatology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Reliability and Availability of the 2017 EULAR-OMERACT Scoring System for Ultrasound Synovitis Assessment: Results From a Training and Reading Exercise.Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2025
    Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Lucio Ventura-RíosLaboratorio de Ultrasonido Musculoesquelético y Articular, Instituto Nacional de Rehabilitación Luis Guillermo Ibarra, Ibarra, Mexico. venturarioslucio@gmail.com.
Cristina Hernández-DíazLaboratorio de Ultrasonido Musculoesquelético y Articular, Instituto Nacional de Rehabilitación Luis Guillermo Ibarra, Ibarra, Mexico.
Diana Ferrusquia-TorízServicio de Medicina Interna, Hospital General de Tlahuác, México City, Mexico.
Esteban Cruz-ArenasUnidad de Vigilancia Epidemiológica Hospitalaria-Investigación Sociomédica, Instituto Nacional de Rehabilitación Luis Guillermo Ibarra, Ibarra, Mexico.
Pedro Rodríguez-HenríquezServicio de Reumatología, Hospital General Dr. Manuel Gea González, México City, Mexico.
Ana Laura Alvarez Del CastilloServicio de Reumatología, Hospital de Especialidades # 25 IMSS, Monterrey, Nuevo León, Mexico.
Alfredo Campaña-ParraHospital General Regional # 20 IMSS, Tijuana, Baja California, Mexico.
Efrén CanulHospital General Regional # 1 IMSS, Mérida, Yucatán, Mexico.
Gerardo Guerrero YeoPráctica privada, Hermosillo, Sonora, Mexico.
Juan Jorge Mendoza-RuizUnidad de Patología Clínica, Guadalajara, Jalisco, Mexico.
Mario Pérez CristóbalServicio de Reumatología, Centro Médico Nacional Siglo XXI, IMSS, México City, Mexico.
Sandra SicsikUnidad Médica de Alta Especialidad # 71 IMSS, Torreón, Coahuila, Mexico.
Karina Silva LunaServicio de Reumatología, Hospital Universitario de Nuevo León, Monterrey, Mexico.
Grupo Mexicano de Ecografía Musculoesquelética AC (ECOMER)

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aims to test the reliability of ultrasound to graduate synovitis in static and video images, evaluating separately grayscale and power Doppler (PD), and combined. Thirteen trained rheumatologist ultrasonographers participated in two separate rounds reading 42 images, 15 static and 27 videos, of the 7-joint count [wrist, 2nd and 3rd metacarpophalangeal (MCP), 2nd and 3rd interphalangeal (IPP), 2nd and 5th metatarsophalangeal (MTP) joints]. The images were from six patients with rheumatoid arthritis, performed by one ultrasonographer. Synovitis definition was according to OMERACT. Scoring system in grayscale, PD separately, and combined (GLOESS-Global OMERACT-EULAR Score System) were reviewed before exercise. Reliability intra- and inter-reading was calculated with Cohen's kappa weighted, according to Landis and Koch. Kappa values for inter-reading were good to excellent. The minor kappa was for GLOESS in static images, and the highest was for the same scoring in videos (k 0.59 and 0.85, respectively). Excellent values were obtained for static PD in 5th MTP joint and for PD video in 2nd MTP joint. Results for GLOESS in general were good to moderate. Poor agreement was observed in 3rd MCP and 3rd IPP in all kinds of images. Intra-reading agreement were greater in grayscale and GLOESS in static images than in videos (k 0.86 vs. 0.77 and k 0.86 vs. 0.71, respectively), but PD was greater in videos than in static images (k 1.0 vs. 0.79). The reliability of the synovitis scoring through static images and videos is in general good to moderate when using grayscale and PD separately or combined.

Indexed as

Arthritis, RheumatoidFoot JointsHand JointsHumansObserver VariationReproducibility of ResultsSynovitisUltrasonographyUltrasonography, DopplerGLOESSReliabilitySynovitis score systems

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.