Evidence map›Paper›PMID 28473334›Full record

ArticleBone & joint research2017

The efficacy of rotational control designs in promoting torsional stability of hip fracture fixation.

J D Gosiewski, T P Holsgrove, H S Gill

Open access · goldAbstract read
In one paragraph

Article in Bone & joint research, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.2field-weighted citation impact, top 41% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 10 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 3 institutions in 2 countries.

J D GosiewskiDepartment of Mechanical Engineering, University of Bath, Claverton Down Rd, Bath, Somerset BA2 7AY, UK j.d.gosiewski@bath.ac.uk.
T P HolsgroveDepartment of Engineering, College of Engineering, Mathematics & Physical Sciences, University of Exeter, and Department of Mechanical Engineering, University of Bath (visiting academic), University of Exeter, College of Engineering, Mathematics & Physical Sciences, Harrison Building, Streatham Campus, University of Exeter, EX4 4QF, UK.
H S GillDepartment of Mechanical Engineering, University of Bath, Claverton Down Rd, Bath, Somerset BA2 7AY, UK.
Physical Sciences (United States) · USUniversity of Bath · GBUniversity of Exeter · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesFractures of the proximal femur are a common clinical problem, and a number of orthopaedic devices are available for the treatment of such fractures. The objective of this study was to assess the rotational stability, a common failure predictor, of three different rotational control design philosophies: a screw, a helical blade and a deployable crucifix.

methodsDevices were compared in terms of the mechanical work (W) required to rotate the implant by 6° in a bone substitute material. The substitute material used was Sawbones polyurethane foam of three different densities (0.08 g/cm

resultsThe deployable crucifix design (X-Bolt), was more torsionally stable, compared to both the dynamic hip screw (DHS, p = 0.008) and helical blade (DHS Blade, p= 0.008) designs in bone substitute material representative of osteoporotic bone (0.16 g/cm

conclusionsOur findings indicate that the clinical standard proximal fracture fixator design, the screw (DHS), was the least effective at resisting torsional load, and a novel crucifix design (X-Bolt), was the most effective design in resisting torsional load in bone substitute material with density representative of osteoporotic bone. At other densities the torsional stability was also higher for the X-Bolt, although not consistently significant by statistical analysis.