Evidence map›Paper›PMID 28472862›Full record

SynthesisThe Cochrane database of systematic reviews2017

Three-dimensional saline infusion sonography compared to two-dimensional saline infusion sonography for the diagnosis of focal intracavitary lesions.

Lotte L Nieuwenhuis, Frederik Jr Hermans, A J Marjolein Bij de Vaate, Mariska Mg Leeflang, Hans Am Brölmann, Wouter Jk Hehenkamp, Ben Willem J Mol, T Justin Clark, Judith Af Huirne

Open access · bronzeAbstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
7.9field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 57 citations in OpenAlex.

  1. From prevalence to precision: Integrating phenotype, symptoms, reproductive goals, and treatment in leiomyoma care.International journal of gynaecology and obstetrics: the official organ of the International Federation of Gynaecology and Obstetrics · 2026
    Review
  2. ISUOG Consensus Statement on sonographic assessment of the endometrium: how to perform a gynecological ultrasound scan and report the findings.Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology · 2026
    Article
  3. Diagnosis and classification of uterine fibroids.International journal of gynaecology and obstetrics: the official organ of the International Federation of Gynaecology and Obstetrics · 2025
    Review
  4. Single-cell sequencing reveals a regulatory role of WT1 in mast cell proliferation in endometrial polyps.FASEB journal : official publication of the Federation of American Societies for Experimental Biology · 2025
    Article
  5. Review
  6. Abnormal uterine bleeding: The well-known and the hidden face.Journal of endometriosis and uterine disorders · 2024
    Article
  7. Review
  8. Contemporary evaluation of women and girls with abnormal uterine bleeding: FIGO Systems 1 and 2.International journal of gynaecology and obstetrics: the official organ of the International Federation of Gynaecology and Obstetrics · 2023
    Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 3 countries.

Lotte L NieuwenhuisDepartment of Obstetrics and Gynaecology, VU University Medical Center, De Boelelaan 1117, Amsterdam, Netherlands, 1081 HZ.
Frederik Jr HermansDepartment of Obstetrics and Gynaecology, Academic Medical Center, PO Box 22660, Amsterdam, Netherlands.
A J Marjolein Bij de VaateDepartment of Obstetrics and Gynaecology, VU University Medical Center, De Boelelaan 1117, Amsterdam, Netherlands, 1081 HZ.
Mariska Mg LeeflangDepartment of Clinical Epidemiology, Biostatistics and Bioinformatics, Academic Medical Center, University of Amsterdam, P.O. Box 22700, Amsterdam, Netherlands, 1100 DE.
Hans Am BrölmannDepartment of Obstetrics and Gynaecology, VU University Medical Center, De Boelelaan 1117, Amsterdam, Netherlands, 1081 HZ.
Wouter Jk HehenkampDepartment of Obstetrics and Gynaecology, VU University Medical Center, De Boelelaan 1117, Amsterdam, Netherlands, 1081 HZ.
Ben Willem J MolDiscipline of Obstetrics and Gynaecology, School of Medicine, Robinson Research Institute, The University of Adelaide, Level 3, Medical School South Building, Frome Road, Adelaide, South Australia, Australia, SA 5005.
T Justin ClarkBirmingham Women's Hospital, Metchley Park Road, Edgbaston, Birmingham, UK, B15 2TG.
Judith Af HuirneDepartment of Obstetrics and Gynaecology, VU University Medical Center, De Boelelaan 1117, Amsterdam, Netherlands, 1081 HZ.
Amsterdam UMC Location VUmc · NLAcademic Medical Center · NLBirmingham Women's Hospital · GBUniversity of Adelaide · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundFocal abnormalities most commonly acquired within the uterine cavity include endometrial polyps (arising from the endometrium) and submucous fibroids (arising from the myometrium). These benign abnormalities can cause several problems, including abnormal uterine bleeding (AUB) and subfertility. Two-dimensional saline infusion sonography (2D SIS) is a minimally invasive test that can be used to diagnose these pathologies, but it is less accurate than hysteroscopy, which is a more invasive procedure by which an endoscope allows direct visualisation of the uterine cavity. Three-dimensional (3D) SIS appears to enhance sonographic visualisation within the uterine cavity, thereby offering a potentially more accurate minimally invasive diagnostic test.

objectivesPrimary objectives • To evaluate the diagnostic accuracy of 3D SIS (index test 1) compared with 2D SIS for the diagnosis of focally growing lesions (presence or not) in women with AUB or subfertility, with hysteroscopy performed as the reference test. • To evaluate the diagnostic accuracy of 2D+3D SIS (index test 2) compared with 2D SIS for the diagnosis of focally growing lesions (presence or not) in women with AUB or subfertility, with hysteroscopy performed as the reference test. In this case, any abnormality on either modality was regarded as a positive result ('OR' approach). Secondary objectives • To evaluate the diagnostic accuracy of 3D SIS (index test 1) compared with 2D SIS according to type of abnormality and discrimination between uterine polyps and submucous fibroids in women with AUB or subfertility, with hysteroscopy and histology used as the reference.• To evaluate the diagnostic accuracy of 2D+3D SIS (index test 2) compared with 2D SIS according to type of abnormality and discrimination between uterine polyps and submucous fibroids in women with AUB or subfertility, with hysteroscopy and histology used as the reference. SEARCH

methodsWe searched the following databases: Cochrane Central Register of Studies Online (CENTRAL CRSO), MEDLINE, Embase, PubMed, Cochrane Gynaecology and Fertility Group (CGF) Specialised Register and CGFG Diagnostic Test Accuracy (DTA) Specialised Register, clinicaltrials.gov and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP). Screening reference lists of appropriate studies was also performed. We screened for eligibility all studies identified from inception until March 2016. We performed searches with no date or language restrictions. SELECTION CRITERIA: The population of interest consisted of premenopausal women with AUB or subfertility and postmenopausal women with AUB. Diagnostic test accuracy studies, randomised controlled trials (RCTs) and prospective cohort studies were eligible for inclusion if they evaluated the accuracy of both 2D SIS and 3D SIS for the diagnosis of acquired intracavitary abnormalities with hysteroscopy used as the reference standard. In light of the lack of data for 3D SIS, we also included studies that evaluated the accuracy of 3D SIS alone. DATA COLLECTION AND ANALYSIS: Two review authors read all potentially eligible references after performing a first screening by title and abstract (LLN and FJRH). They independently extracted data to construct 2×2 tables from eligible studies and assessed studies for methodological quality using the QUADAS-2 tool (revised tool for quality assessment of diagnostic accuracy studies). To describe and visually present results, we produced in RevMan forest plots showing pairs of sensitivity and specificity together with 95% confidence intervals from each study, as well as raw receiver operating characteristic (ROC) plots. We displayed paired analyses in an ROC plot by linking sensitivity-specificity pairs from each study by using a dashed line. To compare 3D SIS versus 2D SIS, we restricted analyses to studies that provided 2×2 tables for both tests and used the bivariate meta-analysis of sensitivity and specificity. MAIN

resultsThirteen studies (1053 women) reported the accuracy of 3D SIS for focal uterine abnormalities; 11 of these (846 women) were suitable for meta-analysis, and eight reported accuracy according to the type of focal abnormality. The design of the included studies seems applicable. The main problem involving the quality of included studies is insufficient reporting of study methods, resulting in unclear risk of bias for several of the quality domains assessed. Therefore, we considered the overall quality of the evidence as low. The summary estimate (11 studies reporting absence or presence of abnormality at 3D SIS) for sensitivity was 94.5% (95% confidence interval (CI) 90.6% to 96.9%) and for specificity 99.4% (95% CI 96.2% to 99.9%). Meta-analysis of the eight studies (N = 716) directly comparing 2D SIS versus 3D SIS showed summary sensitivity of 96.9% (95% CI 91.9% to 98.8%) and summary specificity of 99.5% (95% CI 96.1% to 100%) for 3D SIS. For 2D SIS, summary sensitivity was 90.9% (95% CI 81.2% to 95.8%) and summary specificity was 96.3% (95% CI 86.1% to 99.1%). The difference in accuracy between 2D SIS and 3D SIS was non-significant (P values of 0.07 for sensitivity and 0.10 for specificity). AUTHORS'

conclusionsLow-quality evidence suggests that 3D SIS may be very accurate in detecting intracavitary abnormalities. Meta-analysis revealed no statistically significant differences between 2D SIS and 3D SIS. Summary sensitivity and summary specificity are higher for 3D SIS, but margins of improvement are limited because 2D SIS is already very accurate. When the technology and appropriate expertise are available, 3D SIS offers an alternative to 2D SIS. Both 2D SIS and 3D SIS should be considered alternatives to diagnostic hysteroscopy when intracavitary pathology is suspected in subfertile women and in those with abnormal uterine bleeding.

Indexed as

EndometriumFemaleHumansHysteroscopyLeiomyomaObservational Studies as TopicPolypsProspective StudiesRandomized Controlled Trials as TopicReference StandardsROC CurveSensitivity and SpecificitySodium ChlorideSolutionsUltrasonography, InterventionalUterine DiseasesSodium ChlorideSolutions

Identifiers

PMID28472862
PMCPMC6481510
OpenAlexW2610995925

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.