SynthesisThe Cochrane database of systematic reviews2017
Three-dimensional saline infusion sonography compared to two-dimensional saline infusion sonography for the diagnosis of focal intracavitary lesions.
Synthesis in The Cochrane database of systematic reviews, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 57 citations in OpenAlex.
- From prevalence to precision: Integrating phenotype, symptoms, reproductive goals, and treatment in leiomyoma care.International journal of gynaecology and obstetrics: the official organ of the International Federation of Gynaecology and Obstetrics · 2026Review
- ISUOG Consensus Statement on sonographic assessment of the endometrium: how to perform a gynecological ultrasound scan and report the findings.Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology · 2026Article
- Diagnosis and classification of uterine fibroids.International journal of gynaecology and obstetrics: the official organ of the International Federation of Gynaecology and Obstetrics · 2025Review
- Single-cell sequencing reveals a regulatory role of WT1 in mast cell proliferation in endometrial polyps.FASEB journal : official publication of the Federation of American Societies for Experimental Biology · 2025Article
- Tailoring the Diagnostic Pathway for Medical and Surgical Treatment of Uterine Fibroids: A Narrative Review.Diagnostics (Basel, Switzerland) · 2024Review
- Abnormal uterine bleeding: The well-known and the hidden face.Journal of endometriosis and uterine disorders · 2024Article
- Abnormal Uterine Bleeding: A Pictorial Review on Differential Diagnosis and Not-So-Common Cases of Interventional Radiology Management.Diagnostics (Basel, Switzerland) · 2024Review
- Contemporary evaluation of women and girls with abnormal uterine bleeding: FIGO Systems 1 and 2.International journal of gynaecology and obstetrics: the official organ of the International Federation of Gynaecology and Obstetrics · 2023Article
- Artificial intelligence diagnosis of intrauterine adhesion by 3D ultrasound imaging: a prospective study.Quantitative imaging in medicine and surgery · 2023Article
- Does hysteroscopic resection of polyps require cycle cancellation in women undergoing controlled ovarian hyperstimulation in the ICSI cycle?Turkish journal of obstetrics and gynecology · 2022Article
- Modern assessment of the uterine cavity and fallopian tubes in the era of high-efficacy assisted reproductive technology.Fertility and sterility · 2022Review
- Article
- Histological Sampling of Endometrial Tissue: Comparison between the MedGyn® Endosampler and Formal Fractional Curettage in Patients with Abnormal Uterine Bleeding.Asian Pacific journal of cancer prevention : APJCP · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 4 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundFocal abnormalities most commonly acquired within the uterine cavity include endometrial polyps (arising from the endometrium) and submucous fibroids (arising from the myometrium). These benign abnormalities can cause several problems, including abnormal uterine bleeding (AUB) and subfertility. Two-dimensional saline infusion sonography (2D SIS) is a minimally invasive test that can be used to diagnose these pathologies, but it is less accurate than hysteroscopy, which is a more invasive procedure by which an endoscope allows direct visualisation of the uterine cavity. Three-dimensional (3D) SIS appears to enhance sonographic visualisation within the uterine cavity, thereby offering a potentially more accurate minimally invasive diagnostic test.
objectivesPrimary objectives • To evaluate the diagnostic accuracy of 3D SIS (index test 1) compared with 2D SIS for the diagnosis of focally growing lesions (presence or not) in women with AUB or subfertility, with hysteroscopy performed as the reference test. • To evaluate the diagnostic accuracy of 2D+3D SIS (index test 2) compared with 2D SIS for the diagnosis of focally growing lesions (presence or not) in women with AUB or subfertility, with hysteroscopy performed as the reference test. In this case, any abnormality on either modality was regarded as a positive result ('OR' approach). Secondary objectives • To evaluate the diagnostic accuracy of 3D SIS (index test 1) compared with 2D SIS according to type of abnormality and discrimination between uterine polyps and submucous fibroids in women with AUB or subfertility, with hysteroscopy and histology used as the reference.• To evaluate the diagnostic accuracy of 2D+3D SIS (index test 2) compared with 2D SIS according to type of abnormality and discrimination between uterine polyps and submucous fibroids in women with AUB or subfertility, with hysteroscopy and histology used as the reference. SEARCH
methodsWe searched the following databases: Cochrane Central Register of Studies Online (CENTRAL CRSO), MEDLINE, Embase, PubMed, Cochrane Gynaecology and Fertility Group (CGF) Specialised Register and CGFG Diagnostic Test Accuracy (DTA) Specialised Register, clinicaltrials.gov and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP). Screening reference lists of appropriate studies was also performed. We screened for eligibility all studies identified from inception until March 2016. We performed searches with no date or language restrictions. SELECTION CRITERIA: The population of interest consisted of premenopausal women with AUB or subfertility and postmenopausal women with AUB. Diagnostic test accuracy studies, randomised controlled trials (RCTs) and prospective cohort studies were eligible for inclusion if they evaluated the accuracy of both 2D SIS and 3D SIS for the diagnosis of acquired intracavitary abnormalities with hysteroscopy used as the reference standard. In light of the lack of data for 3D SIS, we also included studies that evaluated the accuracy of 3D SIS alone. DATA COLLECTION AND ANALYSIS: Two review authors read all potentially eligible references after performing a first screening by title and abstract (LLN and FJRH). They independently extracted data to construct 2×2 tables from eligible studies and assessed studies for methodological quality using the QUADAS-2 tool (revised tool for quality assessment of diagnostic accuracy studies). To describe and visually present results, we produced in RevMan forest plots showing pairs of sensitivity and specificity together with 95% confidence intervals from each study, as well as raw receiver operating characteristic (ROC) plots. We displayed paired analyses in an ROC plot by linking sensitivity-specificity pairs from each study by using a dashed line. To compare 3D SIS versus 2D SIS, we restricted analyses to studies that provided 2×2 tables for both tests and used the bivariate meta-analysis of sensitivity and specificity. MAIN
resultsThirteen studies (1053 women) reported the accuracy of 3D SIS for focal uterine abnormalities; 11 of these (846 women) were suitable for meta-analysis, and eight reported accuracy according to the type of focal abnormality. The design of the included studies seems applicable. The main problem involving the quality of included studies is insufficient reporting of study methods, resulting in unclear risk of bias for several of the quality domains assessed. Therefore, we considered the overall quality of the evidence as low. The summary estimate (11 studies reporting absence or presence of abnormality at 3D SIS) for sensitivity was 94.5% (95% confidence interval (CI) 90.6% to 96.9%) and for specificity 99.4% (95% CI 96.2% to 99.9%). Meta-analysis of the eight studies (N = 716) directly comparing 2D SIS versus 3D SIS showed summary sensitivity of 96.9% (95% CI 91.9% to 98.8%) and summary specificity of 99.5% (95% CI 96.1% to 100%) for 3D SIS. For 2D SIS, summary sensitivity was 90.9% (95% CI 81.2% to 95.8%) and summary specificity was 96.3% (95% CI 86.1% to 99.1%). The difference in accuracy between 2D SIS and 3D SIS was non-significant (P values of 0.07 for sensitivity and 0.10 for specificity). AUTHORS'
conclusionsLow-quality evidence suggests that 3D SIS may be very accurate in detecting intracavitary abnormalities. Meta-analysis revealed no statistically significant differences between 2D SIS and 3D SIS. Summary sensitivity and summary specificity are higher for 3D SIS, but margins of improvement are limited because 2D SIS is already very accurate. When the technology and appropriate expertise are available, 3D SIS offers an alternative to 2D SIS. Both 2D SIS and 3D SIS should be considered alternatives to diagnostic hysteroscopy when intracavitary pathology is suspected in subfertile women and in those with abnormal uterine bleeding.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.