Evidence map›Paper›PMID 28469288›Full record

ArticleTribology international2017

Friction properties of a new silk fibroin scaffold for meniscal replacement.

Daniela Warnecke, N B Schild, S Klose, H Joos, R E Brenner, O Kessler, N Skaer, R Walker, M Freutel, A Ignatius and 1 more

Abstract read
In one paragraph

Article in Tribology international, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Anisotropic wear behavior of meniscus: Influence of cross-shear and loading magnitude.Journal of the mechanical behavior of biomedical materials · 2026
    Article
  2. Article
  3. Article
  4. Article
  5. Impact of hyaluronic acid injection on the knee joint friction.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2023
    Article
  6. Article
  7. Article
  8. Natural biopolymer scaffold for meniscus tissue engineering.Frontiers in bioengineering and biotechnology · 2022
    Review
  9. Review
  10. Meniscal Replacement With a Silk Fibroin Scaffold Reduces Contact Stresses in the Human Knee.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2019
    Article
  11. Article
  12. Article
  13. Review
  14. Naturally-Derived Biomaterials for Tissue Engineering Applications.Advances in experimental medicine and biology
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Daniela WarneckeInstitute of Orthopaedic Research and Biomechanics, Centre for Trauma Research Ulm, Ulm University Medical Centre, Germany.
N B SchildInstitute of Orthopaedic Research and Biomechanics, Centre for Trauma Research Ulm, Ulm University Medical Centre, Germany.
S KloseInstitute of Orthopaedic Research and Biomechanics, Centre for Trauma Research Ulm, Ulm University Medical Centre, Germany.
H JoosDivision for Biochemistry of Joint and Connective Tissue Diseases, Department of Orthopaedics, Ulm University Medical Centre, Germany.
R E BrennerDivision for Biochemistry of Joint and Connective Tissue Diseases, Department of Orthopaedics, Ulm University Medical Centre, Germany.
O KesslerCentre of Orthopaedics and Sports, Zurich, Switzerland.
N SkaerOrthox Ltd. Abingdon, UK.
R WalkerOrthox Ltd. Abingdon, UK.
M FreutelInstitute of Orthopaedic Research and Biomechanics, Centre for Trauma Research Ulm, Ulm University Medical Centre, Germany.
A IgnatiusInstitute of Orthopaedic Research and Biomechanics, Centre for Trauma Research Ulm, Ulm University Medical Centre, Germany.
L DürselenInstitute of Orthopaedic Research and Biomechanics, Centre for Trauma Research Ulm, Ulm University Medical Centre, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The menisci protect the articular cartilage by reducing contact pressure in the knee. To restore their function after injury, a new silk fibroin replacement scaffold was developed. To elucidate its tribological properties, friction of the implant was tested against cartilage and glass, where the latter is typically used in tribological cartilage studies. The silk scaffold exhibited a friction coefficient against cartilage of 0.056, which is higher than meniscus against cartilage but in range of the requirements for meniscal replacements. Further, meniscus friction against glass was lower than cartilage against glass, which correlated with the surface lubricin content. Concluding, the tribological properties of the new material suggest a possible long-term chondroprotective function. In contrast, glass always produced high, non-physiological friction coefficients.

Indexed as

CartilageFrictionLubricinMeniscus replacementSilk

Identifiers

PMID28469288
PMCPMC5327953

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.