Evidence map›Paper›PMID 28468649›Full record

ArticleBMC infectious diseases2017

An easy tool to assess ventilation in health facilities as part of air-borne transmission prevention: a cross-sectional survey from Uganda.

Miranda Brouwer, Achilles Katamba, Elly Tebasoboke Katabira, Frank van Leth

Abstract read
In one paragraph

Article in BMC infectious diseases, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Implementation Status of Airborne Infection Control Measures in Primary and Secondary Public Health Facilities, Puducherry: A Mixed-Methods Study.Indian journal of community medicine : official publication of Indian Association of Preventive & Social Medicine
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Miranda BrouwerPHTB Consult, Lovensestraat 79, 5014, DN, Tilburg, The Netherlands. mbrouwer@phtbconsult.org.ORCID 0000-0001-8260-4649
Achilles KatambaDepartment of Medicine, School of Medicine, Makerere University, College of Health Sciences, P.O. Box 21696, Kampala, Uganda.
Elly Tebasoboke KatabiraDepartment of Medicine, School of Medicine, Makerere University, College of Health Sciences, P.O. Box 21696, Kampala, Uganda.
Frank van LethAmsterdam Institute of Global Health and Development, Pietersbergweg 17, 1100, DE, Amsterdam, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundNo guidelines exist on assessing ventilation through air changes per hour (ACH) using a vaneometer. The objective of the study was to evaluate the position and frequency for measuring air velocity using a vaneometer to assess ventilation with ACH; and to assess influence of ambient temperature and weather on ACH.

methodsCross-sectional survey in six urban health facilities in Kampala, Uganda. Measurements consisted of taking air velocity on nine separate moments in five positions in each opening of the TB clinic, laboratory, outpatient consultation and outpatient waiting room using a vaneometer. We assessed in addition the ventilation with the "20% rule", and compared this estimation with the ventilation in ACH assessed using the vaneometer.

resultsA total of 189 measurements showed no influence on air velocity of the position and moment of the measurement. No significant influence existed of ambient temperature and a small but significant influence of sunny weather. Ventilation was adequate in 17/24 (71%) of all measurements. Using the "20% rule", ventilation was adequate in 50% of rooms assessed. Agreement between both methods existed in 13/23 (56%) of the rooms assessed.

conclusionMost rooms had adequate ventilation when assessed using a vaneometer for measuring air velocity. A single vaneometer measurement of air velocity is adequate to assess ventilation in this setting. These findings provide practical input for clear guidelines on assessing ventilation using a vaneometer. Assessing ventilation with a vaneometer differs substantially from applying the "20% rule".

Indexed as

Health FacilitiesCitiesCross-Sectional StudiesHumansInfection ControlSurveys and QuestionnairesTuberculosisUgandaVentilationInfection controlTuberculosisUgandaVentilation

Identifiers

PMID28468649
PMCPMC5415815

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.