Evidence map›Paper›PMID 28455631›Full record

ArticleThe international journal of cardiovascular imaging2017

Real-time three dimensional CT and MRI to guide interventions for congenital heart disease and acquired pulmonary vein stenosis.

Patcharapong Suntharos, Randolph M Setser, Sharon Bradley-Skelton, Lourdes R Prieto

Abstract readValidation Study
PubMed Publisher
In one paragraph

Article in The international journal of cardiovascular imaging, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
0.7field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it, 10 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Patcharapong SuntharosDepartment of Pediatric Cardiology, Cleveland Clinic Children's, 9500 Euclid Avenue, Desk M-41, Cleveland, OH, 44195, USA. sunthap@ccf.org.ORCID http://orcid.org/0000-0003-3412-4637
Randolph M SetserSiemens Medical Solutions USA, Inc., Malvern, PA, USA.
Sharon Bradley-SkeltonDepartment of Pediatric Cardiology, Cleveland Clinic Children's, 9500 Euclid Avenue, Desk M-41, Cleveland, OH, 44195, USA.
Lourdes R PrietoDepartment of Pediatric Cardiology, Cleveland Clinic Children's, 9500 Euclid Avenue, Desk M-41, Cleveland, OH, 44195, USA.
Cleveland Clinic · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To validate the feasibility and spatial accuracy of pre-procedural 3D images to 3D rotational fluoroscopy registration to guide interventional procedures in patients with congenital heart disease and acquired pulmonary vein stenosis. Cardiac interventions in patients with congenital and structural heart disease require complex catheter manipulation. Current technology allows registration of the anatomy obtained from 3D CT and/or MRI to be overlaid onto fluoroscopy. Thirty patients scheduled for interventional procedures from 12/2012 to 8/2015 were prospectively recruited. A C-arm CT using a biplane C-arm system (Artis zee, VC14H, Siemens Healthcare) was acquired to enable 3D3D registration with pre-procedural images. Following successful image fusion, the anatomic landmarks marked in pre-procedural images were overlaid on live fluoroscopy. The accuracy of image registration was determined by measuring the distance between overlay markers and a reference point in the image. The clinical utility of the registration was evaluated as either "High", "Medium" or "None". Seventeen patients with congenital heart disease and 13 with acquired pulmonary vein stenosis were enrolled. Accuracy and benefit of registration were not evaluated in two patients due to suboptimal images. The distance between the marker and the actual anatomical location was 0-2 mm in 18 (64%), 2-4 mm in 3 (11%) and >4 mm in 7 (25%) patients. 3D3D registration was highly beneficial in 18 (64%), intermediate in 3 (11%), and not beneficial in 7 (25%) patients. 3D3D registration can facilitate complex congenital and structural interventions. It may reduce procedure time, radiation and contrast dose.

Indexed as

AdolescentAdultAgedAnatomic LandmarksCardiac CatheterizationChildComputed Tomography AngiographyEndovascular ProceduresFeasibility StudiesFemaleHeart Defects, CongenitalHumansImaging, Three-DimensionalMagnetic Resonance Imaging, InterventionalMaleMiddle Aged3D3D registrationAcquired pulmonary vein stenosisCongenital heart diseaseIntervention

Identifiers

PMID28455631
OpenAlexW2609369281

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.