Evidence map›Paper›PMID 28452339›Full record

ArticlePhysics in medicine and biology2017

Advanced optical simulation of scintillation detectors in GATE V8.0: first implementation of a reflectance model based on measured data.

Mariele Stockhoff, Sebastien Jan, Albertine Dubois, Simon R Cherry, Emilie Roncali

Abstract read
In one paragraph

Article in Physics in medicine and biology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed.

  1. Article
  2. Current Status of Cherenkov-Based Gamma Detectors for TOF-PET and Proton Range Verification.IEEE transactions on radiation and plasma medical sciences · 2026
    Article
  3. Article
  4. Implementation of Photonic Crystals into Davis LUT module for GATE simulation.IEEE transactions on radiation and plasma medical sciences · 2025
    Article
  5. Article
  6. Article
  7. Timing Estimation and Limits in TOF-PET Detectors Producing Prompt Photons.IEEE transactions on radiation and plasma medical sciences · 2023
    Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Study of Čerenkov Light Emission in the Semiconductors TlBr and TlCl for TOF-PET.IEEE transactions on radiation and plasma medical sciences · 2021
    Article
  14. Article
  15. Review
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Mariele StockhoffDepartment of Biomedical Engineering, University of California Davis, One Shields Avenue, Davis, CA 95616, United States of America.
Sebastien Jan2 IMIV, CEA, Inserm, CNRS, Univ. Paris-Sud, Université Paris Saclay, CEA-SHFJ, 91 400, Orsay, France.
Albertine DuboisIMNC, Orsay 91406, France.
Simon R CherryDepartment of Biomedical Engineering, University of California Davis, One Shields Avenue, Davis, CA 95616, United States of America.
Emilie RoncaliDepartment of Biomedical Engineering, University of California Davis, One Shields Avenue, Davis, CA 95616, United States of America.

Funding

Research at the interface of optical and ionizing radiation for innovative cancer imaging and therapyR35CA197608 · NCI · UNIVERSITY OF CALIFORNIA AT DAVIS · PI CHERRY, SIMON R · 2015 to 2021
$4.9M
Modeling of Light Transport in Nuclear Medicine Scintillation DetectorsR03EB020097 · NIBIB · UNIVERSITY OF CALIFORNIA AT DAVIS · PI RONCALI, EMILIE · 2015 to 2016
$157k
NCI NIH HHS R35 CA197608NIBIB NIH HHS R03 EB020097
6 · The paper itself

Abstract

Typical PET detectors are composed of a scintillator coupled to a photodetector that detects scintillation photons produced when high energy gamma photons interact with the crystal. A critical performance factor is the collection efficiency of these scintillation photons, which can be optimized through simulation. Accurate modelling of photon interactions with crystal surfaces is essential in optical simulations, but the existing UNIFIED model in GATE is often inaccurate, especially for rough surfaces. Previously a new approach for modelling surface reflections based on measured surfaces was validated using custom Monte Carlo code. In this work, the LUT Davis model is implemented and validated in GATE and GEANT4, and is made accessible for all users in the nuclear imaging research community. Look-up-tables (LUTs) from various crystal surfaces are calculated based on measured surfaces obtained by atomic force microscopy. The LUTs include photon reflection probabilities and directions depending on incidence angle. We provide LUTs for rough and polished surfaces with different reflectors and coupling media. Validation parameters include light output measured at different depths of interaction in the crystal and photon track lengths, as both parameters are strongly dependent on reflector characteristics and distinguish between models. Results from the GATE/GEANT4 beta version are compared to those from our custom code and experimental data, as well as the UNIFIED model. GATE simulations with the LUT Davis model show average variations in light output of  <2% from the custom code and excellent agreement for track lengths with R

Indexed as

Monte Carlo MethodOptical PhenomenaPhotonsScintillation CountingPositron-Emission Tomography

Identifiers

PMID28452339
PMCPMC9719735

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.