ArticleOrthopaedic journal of sports medicine2017
Tape Versus Suture in Arthroscopic Rotator Cuff Repair: Biomechanical Analysis and Assessment of Failure Rates at 6 Months.
Article in Orthopaedic journal of sports medicine, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 44 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
44 citing papers in PubMed, 68 citations in OpenAlex.
- Round versus tape sutures with interference fit anchors perform similarly in cadaveric glenoid and greater tuberosity biomechanical testing.Archives of orthopaedic and trauma surgery · 2026Article
- Failure Rate After Shoulder Stabilization Procedures in the Military With Use of Knotless Suture Tape: A Case-Control Study.Orthopaedic journal of sports medicine · 2026Article
- Quantitative Ultrasonographic Assessment of Supraspinatus Insertion Tendon in Non-Lame Dogs (Thickness and Relative Echogenicity).Animals : an open access journal from MDPI · 2026Article
- Comparison of Implant Type, Number and Cost, Suture Number, Surgical Time, Clinical Outcomes of Arthroscopic Double-Pulley Suture-Bridge and Single-Row in Repair Supraspinatus Tendon Tears: A Novel Suture-Bridge Technique.Indian journal of orthopaedics · 2026Article
- Biomechanical analysis of single-row anchor, double-row anchor, and single-row knotless tape repair techniques for complete subscapularis tears.JSES reviews, reports, and techniques · 2026Article
- UltraTape and sutures combination versus conventional sutures in arthroscopic rotator cuff repair: a 6-month retrospective matched cohort study.Journal of orthopaedic surgery and research · 2025Article
- Arthroscopic Trianchor With 6 Sets of Double-Pulley Suture Bridge Repair of Medium-Sized Supraspinatus Tendon Tears.Arthroscopy techniques · 2025Article
- Suture tape anchors for enhancing healing in rotator cuff tears: a retrospective cohort study.BMC musculoskeletal disorders · 2025Article
- Arthroscopic Double-Pulley Suture-Bridge Repair of Partial Articular Supraspinatus Tendon Avulsions >1.5 cm Using One Medial-Row Anchor.Arthroscopy techniques · 2025Article
- Arthroscopic 4-Anchor Double-Pulley Suture-Bridge Repair of Large Rotator Cuff Tear.Arthroscopy techniques · 2025Article
- Python tooth-inspired fixation device for enhanced rotator cuff repair.Science advances · 2024Article
- SpeedBridge Repair in Degenerative Achilles Tear: A Novel Technique.Journal of orthopaedic case reports · 2024Article
- A systematic review of the biomechanical properties of suture materials used in orthopaedics.Journal of orthopaedics · 2024Review
- Biomechanical comparison of pectoralis major repair techniques: A systematic review and meta-regression.Shoulder & elbow · 2024Article
- The Zipknot Technique: A Modified Tension Band Repair Technique for Isolated Supraspinatus Tears.Arthroscopy techniques · 2024Article
- What is the Optimal Construct to Reduce Failure in Arthroscopic Four Anchor Rotator Cuff Repair?Shoulder & elbow · 2023Article
- Biomechanical effect of increased number of suture strands on rotator cuff repair in a bovine model.Acta orthopaedica et traumatologica turcica · 2023Article
- Biomechanical Comparison of 1.2-mm Suture Tape, 2.0-mm Suture Tape, and 0.5-mm Suture Using Various Arthroscopic Knot Techniques.Orthopaedic journal of sports medicine · 2023Article
- Rotator cuff repairs with all-suture tape anchors: no difference in outcomes between with or without all-suture tape anchors.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2023Article
- Global Compressive Loading from an Ultra-Thin PEEK Button Augment Enhances Fibrocartilage Regeneration of Rotator Cuff Enthesis.Bioengineering (Basel, Switzerland) · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundRotator cuff retears after surgical repair are associated with poorer subjective and objectives clinical outcomes than intact repairs. PURPOSE: The aims of this study were to (1) examine the biomechanical differences between rotator cuff repair using No. 2 suture and tape in an ovine model and (2) compare early clinical outcomes between patients who had rotator cuff repair with tape and patients who had repair with No. 2 suture. STUDY
designControlled laboratory study and cohort study; Level of evidence, 3.
methodsBiomechanical testing of footprint contact pressure and load to failure were conducted with 16 ovine shoulders using a tension band repair technique with 2 different types of sutures (No. 2 suture [FiberWire; Arthrex] and tape [FiberTape; Arthrex]) with the same knotless anchor system. A retrospective study of 150 consecutive patients (tape, n = 50; suture, n = 100) who underwent arthroscopic rotator cuff repair by a single surgeon with tear size larger than 1.5 × 1 cm was conducted. Ultrasound was used to evaluate the repair integrity at 6 months postsurgery.
resultsRotator cuff repair using tape had greater footprint contact pressure (mean ± standard error of the mean, 0.33 ± 0.03 vs 0.11 ± 0.3 MPa;
conclusionRotator cuff repair with the wider tape compared with No. 2 suture did not affect the retear rate at 6 months postsurgery, despite having superior biomechanical properties.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials