ArticleAnalytical chemistry2017
Collagen Membranes with Ribonuclease Inhibitors for Long-Term Stability of Electrochemical Aptamer-Based Sensors Employing RNA.
Article in Analytical chemistry, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed.
- On the Design, Fabrication, and Operation of Electrochemical Aptamer-Based Sensors.ACS sensors · 2025Review
- Polymer Coating for the Long-Term Storage of Immobilized DNA.ACS sensors · 2025Article
- Label-free, real-time monitoring of cytochrome C drug responses in microdissected tumor biopsies with a multi-well aptasensor platform.Science advances · 2024Article
- Advances in electrochemical biosensor design for the detection of the stress biomarker cortisol.Analytical and bioanalytical chemistry · 2024Review
- Microscale, Electrochemical, Aptamer-Based Sensors for Enhanced Small-Molecule Detection at Millisecond Time Scales.ACS sensors · 2023Article
- Article
- Real-Time,ACS sensors · 2022Review
- The challenge of long-term stability for nucleic acid-based electrochemical sensors.Current opinion in electrochemistry · 2022Article
- Biosensors to Monitor Cell Activity in 3D Hydrogel-Based Tissue Models.Sensors (Basel, Switzerland) · 2022Review
- Elucidating the Mechanisms Underlying the Signal Drift of Electrochemical Aptamer-Based Sensors in Whole Blood.ACS sensors · 2021Article
- Nonfaradaic Current Suppression in DNA-Based Electrochemical Assays with a Differential Potentiostat.Analytical chemistry · 2019Article
- Direct, Real-Time Detection of Adenosine Triphosphate Release from Astrocytes in Three-Dimensional Culture Using an Integrated Electrochemical Aptamer-Based Sensor.ACS chemical neuroscience · 2019Article
- Article
- High-Precision Control of Plasma Drug Levels Using Feedback-Controlled Dosing.ACS pharmacology & translational science · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
Abstract
Electrochemical aptamer-based (E-AB) sensors offer advantageous analytical detection abilities due to their rapid response time (seconds to minutes), specificity to a target, and selectivity to function in complex media. Ribonucleic acid (RNA) aptamers employed in this class of sensor offer favorable binding characteristics resulting from the ability of RNA to form stable tertiary folds aided by long-range intermolecular interactions. As a result, RNA aptamers can fold into three-dimensional structures more complex than those of their DNA counterparts and consequently exhibit better binding ability to target analytes. Unfortunately, RNA aptamers are susceptible to degradation by nucleases, and for this reason, RNA-based sensors are scarce or require significant sample pretreatment before use in clinically relevant media. Here, we combine the usefulness of a collagen I hydrogel membrane with entrapped ribonuclease inhibitors (RI) to protect small molecule RNA E-AB sensors from endogenous nucleases in complex media. More specifically, the biocompatibility of the naturally polymerized hydrogel with encapsulated RI promotes the protection of an aminoglycoside-binding RNA E-AB sensor up to 6 h, enabling full sensor function in nuclease-rich environments (undiluted serum) without the need for prior sample preparation or oligonucleotide modification. The use of collagen as a biocompatible membrane represents a general approach to compatibly interface E-AB sensors with complex biological samples.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.