SynthesisUpdates in surgery2017
Neuromonitoring in endoscopic and robotic thyroidectomy.
Synthesis in Updates in surgery, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
19 citing papers in PubMed, 1 synthesis or guideline pooled it, 52 citations in OpenAlex.
- A systematic review and meta-analysis: surgical outcomes comparing transoral robotic and open approaches to thyroidectomy.Journal of robotic surgery · 2026Pooled it
- A High-Quality Endoscopic Image Dataset with Annotated Recurrent Laryngeal Nerve for AI-Assisted Thyroid Surgery.Scientific data · 2026Article
- Use of intraoperative neuromonitoring in robotic thyroidectomy: a systematic review of recurrent laryngeal nerve outcomes.Annals of medicine and surgery (2012) · 2026Article
- Safety and Efficacy of Intraoperative Neuromonitoring: An Umbrella Review.Health science reports · 2025Review
- An institutional experience of intraoperative neurophysiological monitoring application in robotic thyroidectomy: a retrospective case-control study.Annals of surgical treatment and research · 2024Article
- Complication and conversion outcomes in transoral endoscopic thyroidectomy vestibular approach (TOETVA): a retrospective multicenter propensity score-matched cohort study.Updates in surgery · 2024Article
- Patient satisfaction and operator proficiency in gasless transaxillary endoscopic thyroidectomy under IONM: a retrospective cohort study.Frontiers in endocrinology · 2024Article
- Vagus Nerve Stimulation in the Carotid Triangle: An Effective Method for Monitoring the Recurrent Laryngeal Nerve in Thyroid and Parathyroid Surgery.Journal of clinical medicine · 2023Article
- Comparison of intraoperative neural monitoring between endoscopic transoral and bilateral axillo-breast approach thyroidectomy.Surgical endoscopy · 2023Article
- Mechanisms of recurrent laryngeal nerve injury in endoscopic thyroidectomy for papillary thyroid carcinoma: A large data from China.Laryngoscope investigative otolaryngology · 2023Article
- Utility of video-assisted method for identifying and preserving the external branch of the superior laryngeal nerve during thyroidectomy.Frontiers in surgery · 2023Article
- Preoperative ultrasound mapping of the vagus nerve in thyroid surgery.Gland surgery · 2022Article
- Endoscopic thyroidectomy versus traditional open thyroidectomy for identification of the external branch of the superior laryngeal nerve.Surgical endoscopy · 2021Article
- Complications of Transoral Thyroidectomy: Overview and Update.Clinical and experimental otorhinolaryngology · 2021Review
- Experience with the use of intraoperative continuous nerve monitoring in video-assisted neck surgery and external cervical incisions.Laryngoscope investigative otolaryngology · 2021Article
- Informed Consent for Intraoperative Neural Monitoring in Thyroid and Parathyroid Surgery - Consensus Statement of the International Neural Monitoring Study Group.Frontiers in endocrinology · 2021Review
- Clinical Experience of Use of Percutaneous Continuous Nervemonitoring in Robotic Bilateral Axillo-Breast Thyroid Surgery.Frontiers in endocrinology · 2021Article
- Intraoperative neuromonitoring in traditional and miniinvasive thyroidectomy. A single center experience in 1652 nerve at risk.Acta bio-medica : Atenei Parmensis · 2020Article
- Opportunities and challenges of intermittent and continuous intraoperative neural monitoring in thyroid surgery.Gland surgery · 2017Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 7 institutions in 5 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Intraoperative neuromonitoring (IONM) has proven effective for intraoperative verification of RLN function in the conventional thyroid surgery. However, no studies have performed a systematic evidence-based assessment of this novel health technology in endoscopic and robotic thyroidectomy. Evidence-based criteria were used in a systematic review of relevant literature for years 2000-2015. Four electronic databases (CENTRAL, MEDLINE, Cochrane and EMBASE) were used to retrieve relevant reports published from January 1, 2000 to September 1, 2016. The search terms included "endoscopic thyroidectomy", "robotic thyroidectomy", "IONM", "continuous IONM (CIONM)", "neural monitoring", "recurrent laryngeal nerve monitoring", and "superior laryngeal monitoring". The following data were retrieved from eligible studies of patients undergoing endoscopic or robotic thyroidectomy: objective of study, design and setting of study, population, intervention examined, quality of data, follow-up and dropout rate, risk of bias, and outcomes assessed. Of 160 studies retrieved, only 9 (5%) studies used IONM. Eight studies reported 522 nerve at risk (NAR) with IONM. Only three were prospective randomized studies. Reports of IONM endoscopic and robotic procedures included their use for re-surgery and use in both benign and malignant cases. None of the IONM endoscopic procedures involved bilateral palsy. Two studies reported the use of a staged strategy. The rates of recurrent laryngeal palsy were 0-3.6% for transient and 0-0.4% for permanent. Only 30% of the studies performed vagus nerve stimulation, and only 25% performed superior laryngeal nerve monitoring. In addition to the use of IONM as an assistive technology for navigating the anatomy in challenging procedures such as endoscopic and robotic thyroidectomy, IONM has potential use as a routine adjunct to the conventional video-assisted nerve identification in thyroidectomy.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.